Volumetric quantification of global and regional left ventricular function from real-time three-dimensional echocardiographic images

被引:215
作者
Corsi, C
Lang, RM
Veronesi, F
Weinert, L
Caiani, EG
MacEneaney, P
Lamberti, C
Mor-Avi, V
机构
[1] Univ Chicago, Med Ctr, Chicago, IL 60637 USA
[2] Univ Bologna, Dept Elect Comp Sci & Syst, Bologna, Italy
[3] Politecn Milan, Dipartimento Bioingn, I-20133 Milan, Italy
关键词
imaging; echocardiography; magnetic resonance imaging; ventricles; endocardium;
D O I
10.1161/CIRCULATIONAHA.104.513689
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background - Real-time 3D echocardiographic (RT3DE) data sets contain dynamic volumetric information on cardiac function. However, quantification of left ventricular (LV) function from 3D echocardiographic data is performed on cut-planes extracted from the 3D data sets and thus does not fully exploit the volumetric information. Accordingly, we developed a volumetric analysis technique aimed at quantification of global and regional LV function. Methods and Results - RT3DE images obtained in 30 patients (Philips 7500) were analyzed by use of custom software based on the level-set approach for semiautomated detection of LV endocardial surface throughout the cardiac cycle, from which global and regional LV volume (LVV)-time and wall motion (WM) - time curves were obtained. The study design included 3 protocols. In protocol 1, time curves obtained in 16 patients were compared point-by-point with MRI data ( linear regression and Bland-Altman analyses). Global LVV correlated highly with MRI (r = 0.98; y = 0.99x + 2.3) with minimal bias (1.4 mL) and narrow limits of agreement (+/- 20 mL). WM correlated highly only in basal and midventricular segments ( r = 0.88; y = 0.85x + 0.7). In protocol 2, we tested the ability of this technique to differentiate populations with known differences in LV function by studying 9 patients with dilated cardiomyopathy and 9 normal subjects. All calculated indices of global and regional systolic and diastolic LV function were significantly different between the groups. In protocol 3, we tested the feasibility of automated detection of regional WM abnormalities in 11 patients. In each segment, abnormality was detected when regional shortening fraction was below a threshold obtained in normal subjects. The automated detection agreed with expert interpretation of 2D WM in 86% of segments. Conclusions - Volumetric analysis of RT3DE data is clinically feasible and allows fast, semiautomated, dynamic measurement of LVV and automated detection of regional WM abnormalities.
引用
收藏
页码:1161 / 1170
页数:10
相关论文
共 36 条
  • [1] Assessment of ventricular function and mass by cardiac magnetic resonance imaging
    Alfakih, K
    Reid, S
    Jones, T
    Sivananthan, M
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (10) : 1813 - 1822
  • [2] PERFORMANCE OF OPTICAL-FLOW TECHNIQUES
    BARRON, JL
    FLEET, DJ
    BEAUCHEMIN, SS
    [J]. INTERNATIONAL JOURNAL OF COMPUTER VISION, 1994, 12 (01) : 43 - 77
  • [3] Buck T, 1996, J Am Soc Echocardiogr, V9, P488, DOI 10.1016/S0894-7317(96)90120-0
  • [4] Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association
    Cerqueira, MD
    Weissman, NJ
    Dilsizian, V
    Jacobs, AK
    Kaul, S
    Laskey, WK
    Pennell, DJ
    Rumberger, JA
    Ryan, T
    Verani, MS
    [J]. CIRCULATION, 2002, 105 (04) : 539 - 542
  • [5] Using prior shape and intensity profile in medical image segmentation
    Chen, YM
    Huang, F
    Tagare, HD
    Rao, M
    Wilson, D
    Geiser, EA
    [J]. NINTH IEEE INTERNATIONAL CONFERENCE ON COMPUTER VISION, VOLS I AND II, PROCEEDINGS, 2003, : 1117 - 1124
  • [6] Assessment of regional wall motion abnormalities with real-time 3-dimensional echocardiography
    Collins, M
    Hsieh, A
    Ohazama, CJ
    Ota, T
    Stetten, G
    Donovan, CL
    Kisslo, J
    Ryan, T
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (01) : 7 - 14
  • [7] Left ventricular volume estimation for real-time three-dimensional echocardiography
    Corsi, C
    Saracino, G
    Sarti, A
    Lamberti, C
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (09) : 1202 - 1208
  • [8] Tissue Doppler echocardiography
    Erbel, R
    Wallbridge, DR
    Zamorano, J
    Drozdz, J
    Nesser, HJ
    [J]. HEART, 1996, 76 (03) : 193 - 196
  • [9] ECHOVENTRICULOGRAPHY - A SIMULTANEOUS ANALYSIS OF TWO-DIMENSIONAL ECHOCARDIOGRAPHY AND CINEVENTRICULOGRAPHY
    ERBEL, R
    SCHWEIZER, P
    LAMBERTZ, H
    HENN, G
    MEYER, J
    KREBS, W
    EFFERT, S
    [J]. CIRCULATION, 1983, 67 (01) : 205 - 215
  • [10] Glantz SA, 1990, PRIMER APPL REGRESSI, P381