Quantitative determination of caffeine on reversed-phase CS thin-layer chromatography plates using a surface sampling electrospray ionization system with tandem mass spectrometry detection is reported. The thin-layer chromatography/electrospray tandem mass spectrometry method employed a deuterium-labeled caffeine internal standard and selected reaction monitoring detection. Up to nine parallel caffeine bands on a single plate were sampled in a single surface scanning experiment requiring 35 min at a surface scan rate of 44 mu m/s. A reversed-phase HPLC/UV caffeine assay was developed in parallel to assess the mass spectrometry method performance. Limits of detection for the HPLC/UV and thin-layer chromatography/electrospray tandem mass spectrometry methods determined from the calibration curve statistics were 0.20 ng injected (0.50 mu L) and 1.0 ng spotted on the plate, respectively. Spike recoveries with standards and real samples ranged between 97 and 106% for both methods. The caffeine content of three diet soft drinks (Diet Coke, Diet Cherry Coke, Diet Pepsi) and three diet sport drinks (Diet Turbo Tea, Speed Stack Grape, Speed Stack Fruit Punch) was measured. The HPLC/UV and mass spectrometry determinations were in general agreement, and these values were consistent with the quoted values for two of the three diet colas. In the case of Diet Cherry Coke and the diet sports drinks, the determined caffeine amounts using both methods were consistently higher (by similar to 8% or more) than the literature values.
引用
收藏
页码:4385 / 4389
页数:5
相关论文
共 17 条
[1]  
BANNO K, 1991, CHROMATOGRAPHIA, V32, P79
[2]  
BROWN S M, 1991, Journal of Planar Chromatography - Modern TLC, V4, P189
[3]   MASS-SPECTROMETRIC DETECTORS FOR SAMPLES SEPARATED BY PLANAR ELECTROPHORESIS [J].
BUSCH, KL .
JOURNAL OF CHROMATOGRAPHY A, 1995, 692 (1-2) :275-290
[4]   Quantitative determination of Piroxicam by TLC-MALDI TOF MS [J].
Crecelius, A ;
Clench, MR ;
Richards, DS ;
Parr, V .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 35 (01) :31-39
[5]  
Ford MJ, 2004, RAPID COMMUN MASS SP, V18, P1303, DOI 10.1002/rcm.1486
[6]  
FORD MJ, IN PRESS J MASS SPEC
[7]  
Fried B., 1999, THIN LAYER CHROMATOG
[8]  
KUSCH P, 2003, CHEM ED, V8, P201
[9]   RESONANT 2-PHOTON IONIZATION SPECTROSCOPIC ANALYSIS OF THIN-LAYER CHROMATOGRAPHY USING PULSED LASER DESORPTION-VOLATILIZATION INTO SUPERSONIC JET EXPANSIONS [J].
LI, L ;
LUBMAN, DM .
ANALYTICAL CHEMISTRY, 1989, 61 (17) :1911-1915
[10]  
MILLER JC, 1908, STAT ANAL CHEM, P110