Quantification of myocardial perfusion with MRI and exogenous contrast agents

被引:20
作者
Vallee, JP
Sostman, HD
MacFall, JR
Coleman, RE
机构
[1] DUKE UNIV,MED CTR,CTR ADV MAGNET RESONANCE DEV,DURHAM,NC
[2] DUKE UNIV,MED CTR,DEPT RADIOL,DIV NUCL MED,DURHAM,NC
关键词
myocardium; perfusion; MRI contrast; media model;
D O I
10.1159/000177315
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This review discusses the applications of MRI to quantification of the myocardial perfusion. The first step of the measurement is to obtain a concentration-time curve from a signal intensity-time (SI) curve. Factors which influence the correlation between SI and the concentration are discussed for relaxivity and susceptibility agents. The second stage of measurement is to extract parameters of myocardial perfusion from the concentration-time curve. Two methods are considered, one for an intravascular agent and the other for an extravascular agent. Key points are illustrated with experimental data.
引用
收藏
页码:90 / 105
页数:16
相关论文
共 117 条
[1]   MYOCARDIAL PERFUSION ASSESSED BY SUBSECOND MAGNETIC-RESONANCE-IMAGING WITH A PARAMAGNETIC MACROMOLECULAR CONTRAST AGENT [J].
ARTEAGA, C ;
CANET, E ;
OVIZE, M ;
JANIER, M ;
REVEL, D .
INVESTIGATIVE RADIOLOGY, 1994, 29 :S54-S57
[2]   1ST-PASS CARDIAC PERFUSION - EVALUATION WITH ULTRAFAST MR IMAGING [J].
ATKINSON, DJ ;
BURSTEIN, D ;
EDELMAN, RR .
RADIOLOGY, 1990, 174 (03) :757-762
[4]  
Bergmann S R, 1994, Am J Card Imaging, V8, P181
[5]   NONINVASIVE QUANTITATION OF MYOCARDIAL BLOOD-FLOW IN HUMAN-SUBJECTS WITH OXYGEN-15-LABELED WATER AND POSITRON EMISSION TOMOGRAPHY [J].
BERGMANN, SR ;
HERRERO, P ;
MARKHAM, J ;
WEINHEIMER, CJ ;
WALSH, MN .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 14 (03) :639-652
[6]  
BERGMANN SR, 1991, CARDIAC NUCL MED, V1, P299
[7]   INFLUENCE OF BOLUS VOLUME AND DOSE OF GADOLINIUM CHELATE FOR FIRST-PASS MYOCARDIAL PERFUSION MR-IMAGING STUDIES [J].
CANET, E ;
DOUEK, P ;
JANIER, M ;
BENDID, K ;
AMAYA, J ;
MILLET, P ;
REVEL, D .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (04) :411-415
[8]   SUPERPARAMAGNETIC IRON-OXIDE PARTICLES AND POSITIVE ENHANCEMENT FOR MYOCARDIAL PERFUSION STUDIES ASSESSED BY SUBSECOND T-1-WEIGHTED MRI [J].
CANET, E ;
REVEL, D ;
FORRAT, R ;
BALDYPORCHER, C ;
DELORGERIL, M ;
SEBBAG, L ;
VALLEE, JP ;
DIDIER, D ;
AMIEL, M .
MAGNETIC RESONANCE IMAGING, 1993, 11 (08) :1139-1145
[9]   1ST-PASS ENTRY OF NONIONIC CONTRAST AGENT INTO THE MYOCARDIAL EXTRAVASCULAR SPACE - EFFECTS ON RADIOGRAPHIC ESTIMATES OF TRANSIT-TIME AND BLOOD-VOLUME [J].
CANTY, JM ;
JUDD, RM ;
BRODY, AS ;
KLOCKE, FJ .
CIRCULATION, 1991, 84 (05) :2071-2078
[10]   PERMEABILITY OF CAPILLARIES IN VARIOUS ORGANS AS DETERMINED BY USE OF INDICATOR DIFFUSION METHOD [J].
CRONE, C .