A simple combined microdissection and aspiration device for the rapid procurement of single cells from clinical peripheral blood smears

被引:6
作者
Beltinger, CP [1 ]
Debatin, KM [1 ]
机构
[1] Univ Ulm, Kinderklin, D-89075 Ulm, Germany
来源
JOURNAL OF CLINICAL PATHOLOGY-MOLECULAR PATHOLOGY | 1998年 / 51卷 / 04期
关键词
microdissection; single cell; cytology; molecular analysis;
D O I
10.1136/mp.51.4.233
中图分类号
R36 [病理学];
学科分类号
100104 ;
摘要
Molecular analysis of cells from cytology specimens can help to establish a diagnosis in ambiguous cases. However, mutations in heterogeneous samples might not be detected because of the diluting effect of DNA from normal background cells. Even ifa mutation were detected, it could not be traced back to a specific cell type. Molecular analysis of single cells circumvents this problem. Both mechanical and laser assisted methods have been described for the selective procurement of cells from histology slides; however, they have the drawback of either being technically demanding or expensive. Furthermore, it is unclear whether they can be applied to cytology specimens. Finally, few of these techniques are able to procure single cells. Therefore, we developed a simplified combined microdissection and aspiration device for the rapid procurement of single cells from clinical cytology specimens, The principle of this device, called the cytopicker, is the combination of the microdissection tool, a steel cannula, with the aspiration tool, a glass capillary connected to a vacuum, into one device. Steel cannulae are optimal for microdissection of cells from the hard matrix of cytology specimens but aspirate poorly. On the other hand, glass capillaries are suboptimal for dissecting but aspirate very well. Combining both tools into one by inserting the capillary into the cannula allows optimal dissection using the cannula (with the glass capillary withdrawn and thus protected), followed by optimal aspiration using the capillary (after being advanced through the cannula). All movements of the device are controlled by just one micromanipulator, making the cytopicker inexpensive to manufacture. The cytopicker can rapidly and simply procure single cells, such as lymphoblasts, from cytology specimens, such as peripheral blood smears. DNA from these cells can be amplified by PCR. However, precautions have to be taken to avoid contamination. Once improved further, the cytopicker might facilitate molecular analysis in the routine cytology laboratory.
引用
收藏
页码:233 / 236
页数:4
相关论文
共 9 条
[1]  
Becker I, 1996, LAB INVEST, V75, P801
[2]   Whole genome amplification of single cells from clinical peripheral blood smears [J].
Beltinger, CP ;
Klimek, F ;
Debatin, KM .
JOURNAL OF CLINICAL PATHOLOGY-MOLECULAR PATHOLOGY, 1997, 50 (05) :272-275
[3]   THE MORPHOLOGICAL CLASSIFICATION OF ACUTE LYMPHOBLASTIC-LEUKEMIA - CONCORDANCE AMONG OBSERVERS AND CLINICAL CORRELATIONS [J].
BENNETT, JM ;
CATOVSKY, D ;
DANIEL, MT ;
FLANDRIN, G ;
GALTON, DAG ;
GRALNICK, HR ;
SULTAN, C .
BRITISH JOURNAL OF HAEMATOLOGY, 1981, 47 (04) :553-+
[4]  
Bohm M, 1997, AM J PATHOL, V151, P63
[5]   Laser capture microdissection [J].
EmmertBuck, MR ;
Bonner, RF ;
Smith, PD ;
Chuaqui, RF ;
Zhuang, ZP ;
Goldstein, SR ;
Weiss, RA ;
Liotta, LA .
SCIENCE, 1996, 274 (5289) :998-1001
[6]  
Going JJ, 1996, J PATHOL, V179, P121
[7]  
Moskaluk CA, 1997, AM J PATHOL, V150, P1547
[8]  
ZHUANG ZP, 1995, AM J PATHOL, V146, P620
[9]  
ZHUANG ZP, 1994, ACTA CYTOL, V38, P671