Improved prediction of the collagen fiber architecture in the aortic heart valve

被引:54
作者
Driessen, NJB [1 ]
Bouten, CVC [1 ]
Baaijens, FPT [1 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2005年 / 127卷 / 02期
关键词
tissue engineering; aortic heart valve; collagen architecture; collagen fiber remodeling;
D O I
10.1115/1.1865187
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Living tissues show an adaptive response to mechanical loading by changing their internal structure and morphology. Understanding this response is essential for successful tissue engineering of load-bearing structures, such as the aortic valve. In this study, mechanically induced remodeling of the collagen architecture in the aortic valve was investigated. It was hypothesized that, in uniaxially loaded regions, the fibers aligned with the tensile principal stretch direction. For biaxial loading conditions, on the other hand, it was assumed that the collagen fibers aligned with directions situated between the principal stretch directions. This hypothesis has already been applied successfully to study collagen remodeling in arteries. The predicted fiber architecture represented a branching network and resembled the macroscopically visible collagen bundles in the native leaflet. In addition, the complex biaxial mechanical behavior of the native valve could be simulated qualitatively with the predicted fiber directions. The results of the present model might be used to gain further insight into the response of tissue engineered constructs during mechanical conditioning.
引用
收藏
页码:329 / 336
页数:8
相关论文
共 50 条
[1]  
[Anonymous], PATHOLOGY
[2]   An anisotropic biphasic theory of tissue-equivalent mechanics: The interplay among cell traction, fibrillar network deformation, fibril alignment, and cell contact guidance [J].
Barocas, VH ;
Tranquillo, RT .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (02) :137-145
[3]   A finite element solution for the anisotropic biphasic theory of tissue equivalent mechanics: The effect of contact guidance on isometric cell traction measurement [J].
Barocas, VH ;
Tranquillo, RT .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1997, 119 (03) :261-268
[4]  
Bathe K, 2007, Finite element procedures
[5]   Biaxial mechanical properties of the native and glutaraldehyde-treated aortic valve cusp: Part II - A structural constitutive model [J].
Billiar, KL ;
Sacks, MS .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2000, 122 (04) :327-335
[6]  
BILLIAR KL, 2000, ASME, V122, P23
[7]   EXTRACELLULAR COMPARTMENTS IN MATRIX MORPHOGENESIS - COLLAGEN FIBRIL, BUNDLE, AND LAMELLAR FORMATION BY CORNEAL FIBROBLASTS [J].
BIRK, DE ;
TRELSTAD, RL .
JOURNAL OF CELL BIOLOGY, 1984, 99 (06) :2024-2033
[8]   Regulation of cardiovascular collagen synthesis by mechanical load [J].
Bishop, JE ;
Lindahl, G .
CARDIOVASCULAR RESEARCH, 1999, 42 (01) :27-44
[9]   Finite element model of mechanically induced collagen fiber synthesis and degradation in the aortic valve [J].
Boerboom, RA ;
Driessen, NJB ;
Bouten, CVC ;
Huyghe, JM ;
Baaijens, FPT .
ANNALS OF BIOMEDICAL ENGINEERING, 2003, 31 (09) :1040-1053
[10]   COLLAGEN EXPRESSION IN MECHANICALLY STIMULATED CARDIAC FIBROBLASTS [J].
CARVER, W ;
NAGPAL, ML ;
NACHTIGAL, M ;
BORG, TK ;
TERRACIO, L .
CIRCULATION RESEARCH, 1991, 69 (01) :116-122