Ion-exclusion chromatography combined with ICP-MS and hydride generation-ICP-MS for the determination of arsenic species in biological matrices

被引:47
作者
Nakazato, T
Taniguchi, T
Tao, H
Tominaga, M
Miyazaki, A
机构
[1] Natl Inst Resources & Environm, Tsukuba, Ibaraki 3058569, Japan
[2] Shimadzu Co Ltd, Kanagawa 2591304, Japan
关键词
D O I
10.1039/b005981l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive and robust method for the determination;of eight inorganic and organic arsenic species by ion-exclusion liquid chromatography combined with inductively coupled plasma mass spectrometry (LC-ICP-MS) and. LC-hydride generation-ICP-MS (LC-HG-ICP-MS) is described. The species are arsenite (As-III), arsenate (As'), monomethylarsonic acid (MMAs), dimethylarsinic acid (DMAs), arsenobetaine (AsB), trimethylarsine oxide (TMAsO), tetramethylarsonium salt (TMAs) and arsenocholine salt (AsC). A good separation of seven arsenic species, As-III, As-v, MMAs, DMAs, AsB, TMAsO, and AsC or TMAs, was achieved by using an ion-exclusion column packed with a carboxylated methacrylate resin and 0.35 mmol l(-1) of a sodium sulfate solution adjusted to pH 3.8 as the mobile phase. The detection limits of the eight arsenic species obtained by LC-ICP-MS ranged from 0.067 to 0.34 ng As ml(-1) using an injection volume of 50 mul. A hydride generation technique improved the detection limits of As-III, As-v, MMAs, DMAs and TMAsO to 0.016-0.075 ng As ml(-1) while AsB, TMAs and AsC were not detectable. The relative standard deviations of five replicates of a standard of each arsenic species by the former method ranged from 1.3 to 3.3% and those by the latter method, from 1.8 to 3.1%. The proposed methods were successfully applied to the determination of five arsenic species in human urine and six species in an extract from tuna fish tissue. The only necessary pretreatment for these analyses involved filtration with a 0.45 mum membrane and the ArCl polyatomic interference, due to a large amount of chloride in the biological samples on As-75 measurement, was eliminated by the described LC separation. In addition, serious deterioration in column performance and a decrease in the sensitivity of ICP-MS were not observed during the experimental period of five months. The LC-ICP-MS and LC-HG-ICP-MS methods were validated by analyzing reference samples of human urine and tuna fish tissue.
引用
收藏
页码:1546 / 1552
页数:7
相关论文
共 33 条
[1]   Speciation of arsenic in fish tissue using microwave-assisted extraction followed by HPLC-ICP-MS [J].
Ackley, KL ;
B'Hymer, C ;
Sutton, KL ;
Caruso, JA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (05) :845-850
[2]   Determination of urinary arsenic by solvent extraction and electrothermal atomic absorption spectrometry. A comparison with directly coupled high-performance liquid chromatography inductively coupled plasma mass spectrometry [J].
Bavazzano, P ;
Perico, A ;
Rosendahl, K ;
Apostoli, P .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (07) :521-524
[3]   Speciation of arsenic in mussels by the coupled system liquid chromatography UV irradiation hydride generation inductively coupled plasma mass spectrometry [J].
Dagnac, T ;
Padró, A ;
Rubio, R ;
Rauret, G .
TALANTA, 1999, 48 (04) :763-772
[4]  
*FOOD AGR ORG, 1972, WHO FOOD ADD SER, V505
[5]   SEPARATION OF 7 ARSENIC COMPOUNDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ONLINE DETECTION BY HYDROGEN ARGON FLAME ATOMIC-ABSORPTION SPECTROMETRY AND INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY [J].
HANSEN, SH ;
LARSEN, EH ;
PRITZL, G ;
CORNETT, C .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1992, 7 (04) :629-634
[6]   SPECIATION OF ARSENIC IN URINE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRIC DETECTION [J].
HEITKEMPER, D ;
CREED, J ;
CARUSO, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1989, 4 (03) :279-284
[7]  
Inoue Y, 1999, APPL ORGANOMET CHEM, V13, P81, DOI 10.1002/(SICI)1099-0739(199902)13:2<81::AID-AOC802>3.3.CO
[8]  
2-2
[9]   Method optimization and quality assurance in speciation analysis using high performance liquid chromatography with detection by inductively coupled plasma mass spectrometry [J].
Larsen, EH .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (02) :253-265
[10]   SPECIATION OF 8 ARSENIC COMPOUNDS IN HUMAN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRIC DETECTION USING ANTIMONATE FOR INTERNAL CHROMATOGRAPHIC STANDARDIZATION [J].
LARSEN, EH ;
PRITZL, G ;
HANSEN, SH .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1993, 8 (04) :557-563