In vitro and in vivo comparison of three different intravascular ultrasound catheter designs

被引:11
作者
Fort, S
Freeman, NA
Johnston, P
Cohen, EA
Foster, FS
机构
[1] Univ Toronto, Hlth Sci Ctr, Schulich Heart Ctr, Sunnybrook & Womens Coll, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Biophys, Toronto, ON M4N 3M5, Canada
关键词
intravascular ultrasound; high frequency;
D O I
10.1002/ccd.1087
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Intravascular ultrasound (IVUS) is an invasive imaging modality which provides detailed two-dimensional images of blood vessels. There are currently two different types of IVUS catheters available, namely, the phased-array and the mechanical designs. The operating ultrasound frequency of these catheters ranges from 20 to 40 MHz. This study sought to evaluate the image quality, accuracy of diameter and pullback length measurements, and catheter handling characteristics of three different IVUS catheters currently available for clinical use using both in vitro phantom models and in patients undergoing percutaneous coronary intervention (PCI). in gelatin phantom models, image quality assessed on a semiquantitative scale was significantly different between the three IVUS catheters (P = 0.01) with the 40-MHz catheter providing the best images. Accuracy of lumen diameter measurements, when compared to optical microscopy, were similar between the three IVUS catheter designs (all R-2 = 0.99). There were no significant differences in accuracy of pullback length measurements in vitro between the three designs. However, there were differences in the performance of the three IVUS catheters when used for preinterventional imaging in patients undergoing PCI. Both mechanical IVUS catheters were associated with lower procedural, fluoroscopy, and lesion crossing times compared to the phased-array catheter (all P < 0.05). There were no significant differences between the catheters during postinterventional IVUS imaging. There were also small but potentially important differences with regards to clinical events and complications associated with the use of the different IVUS catheters during the PCI procedures, reflecting differences in catheter design. (C) 2001 Wiley-Liss, Inc.
引用
收藏
页码:382 / 392
页数:11
相关论文
共 19 条
  • [1] ANGIOGRAPHIC CHANGES (DOTTER EFFECT) PRODUCED BY INTRAVASCULAR ULTRASOUND IMAGING BEFORE CORONARY ANGIOPLASTY
    ALFONSO, F
    MACAYA, C
    GOICOLEA, J
    HERNANDEZ, R
    BANUELOS, C
    INIGUEZ, A
    ZAMORANO, J
    ZARCO, P
    [J]. AMERICAN HEART JOURNAL, 1994, 128 (02) : 244 - 251
  • [2] Austen W G, 1975, Circulation, V51, P5
  • [3] ANGIOGRAPHIC OCCURRENCE AND CLINICAL CORRELATES OF INTRALUMINAL CORONARY-ARTERY THROMBUS - ROLE OF UNSTABLE ANGINA
    BRESNAHAN, DR
    DAVIS, JL
    HOLMES, DR
    SMITH, HC
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (02) : 285 - 289
  • [4] Intravascular ultrasound-guided optimized stent deployment - Immediate and 6 months clinical and angiographic results from the Multicenter Ultrasound Stenting in Coronaries Study (MUSIC Study)
    de Jaegere, P
    Mudra, H
    Figulla, H
    Almagor, Y
    Doucet, S
    Penn, I
    Colombo, A
    Hamm, C
    Bartorelli, A
    Rothman, M
    Nobuyoshi, M
    Yamaguchi, T
    Voudris, V
    DiMario, C
    Makovski, S
    Hausmann, D
    Rowe, S
    Rabinovich, S
    Sunamura, M
    van Es, GA
    [J]. EUROPEAN HEART JOURNAL, 1998, 19 (08) : 1214 - 1223
  • [5] TRANSLUMINAL TREATMENT OF ARTERIOSCLEROTIC OBSTRUCTION - DESCRIPTION OF NEW TECHNIC + PRELIMINARY REPORT OF ITS APPLICATION
    DOTTER, CT
    JUDKINS, MP
    [J]. CIRCULATION, 1964, 30 (05) : 654 - &
  • [6] ANGIOGRAPHIC AND CLINICAL PREDICTORS OF ACUTE CLOSURE AFTER NATIVE VESSEL CORONARY ANGIOPLASTY
    ELLIS, SG
    ROUBIN, GS
    KING, SB
    DOUGLAS, JS
    WEINTRAUB, WS
    THOMAS, RG
    COX, WR
    [J]. CIRCULATION, 1988, 77 (02) : 372 - 379
  • [7] Fitzgerald PJ, 2000, CIRCULATION, V102, P523
  • [8] THE SAFETY OF INTRACORONARY ULTRASOUND - A MULTICENTER SURVEY OF 2207 EXAMINATIONS
    HAUSMANN, D
    ERBEL, R
    ALIBELLICHEMARIN, MJ
    BOKSCH, W
    CARACCIOLO, E
    COHN, JM
    CULP, SC
    DANIEL, WG
    DESCHEERDER, I
    DIMARIO, C
    FERGUSON, JJ
    FITZGERALD, PJ
    FRIEDRICH, G
    GE, JB
    GORGE, G
    HANRATH, P
    HODGSON, JM
    ISNER, JM
    JAIN, S
    MAIERRUDOLPH, W
    MOONEY, M
    MOSES, JW
    MUDRA, H
    PINTO, FJ
    SMALLING, RW
    TALLEY, JD
    TOBIS, JM
    WALTER, PD
    WEIDINGER, F
    WERNER, GS
    YEUNG, AC
    YOCK, PG
    [J]. CIRCULATION, 1995, 91 (03) : 623 - 630
  • [9] UNRECOGNIZED LEFT MAIN CORONARY-ARTERY DISEASE IN PATIENTS UNDERGOING INTERVENTIONAL PROCEDURES
    HERMILLER, JB
    BULLER, CE
    TENAGLIA, AN
    KISSLO, KB
    PHILLIPS, HR
    BASHORE, TM
    STACK, RS
    DAVIDSON, CJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (02) : 173 - 176
  • [10] IMPACT OF PREINTERVENTION INTRAVASCULAR ULTRASOUND IMAGING ON TRANSCATHETER TREATMENT STRATEGIES IN CORONARY-ARTERY DISEASE
    MINTZ, GS
    PICHARD, AD
    KOVACH, JA
    KENT, KM
    SATLER, LF
    JAVIER, SP
    POPMA, JJ
    LEON, MB
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1994, 73 (07) : 423 - 430