Flow regime at ambient outlet pressure and its influence in comprehensive two-dimensional gas chromatography

被引:72
作者
Beens, J
Janssen, HG
Adahchour, M
Brinkman, UAT
机构
[1] Free Univ Amsterdam, Dept Analyt Chem & Appl Spect, NL-1081 HV Amsterdam, Netherlands
[2] Unilever Res & Dev, Adv Measurement & Imaging, NL-3133 AT Vlaardingen, Netherlands
[3] Univ Amsterdam, Fac Sci, Polymer Anal Grp, NL-1018 WV Amsterdam, Netherlands
关键词
GC x GC; optimum flow; column dimensions; resolution; modulation criterion; sample capacity;
D O I
10.1016/j.chroma.2005.05.086
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
With method development in one-dimensional GC already being a tedious task, developing GC x GC methods is even more laborious. The majority of the present GC x GC applications are derived from previously optimised ID-GC methods, from which especially the carrier gas flow settings are copied. However, in view of the high pressure inside the first-dimension column (high flow resistance of the narrow-bore second-dimension column), diffusion in the first column is much slower than in ID-GC. Proper optimisation of the column combination and the carrier gas flow can considerably improve separations in GC x GC. To assist in the process of selecting column dimensions and flow rate optimization, we have developed a computer programme, based on Excel (R), that enables quick and simple calculation for all types of column combinations. The programme merely needs column dimensions and carrier gas type as input parameters and calculates all resolution and velocity parameters of the GC x GC separation by using flow rate and plate height equations. From the calculations a number of interesting conclusions can be drawn. As an example, the calculations clearly show that the majority of column combinations reported up till now have been operated at a far from optimal flow - and, consequently, a far from optimal resolution. Probably even more important is the conclusion that the majority of column combinations used so far, i.e. those with 100 mu m I.D. second-dimension columns, are not necessarily the best choice for GC x GC. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:141 / 150
页数:10
相关论文
共 22 条
  • [1] Comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometric detection for the trace analysis of flavour compounds in food
    Adahchour, M
    van Stee, LLP
    Beens, J
    Vreuls, RJJ
    Batenburg, MA
    Brinkman, UAT
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2003, 1019 (1-2) : 157 - 172
  • [2] [Anonymous], 1965, DYNAMICS CHROMATOGRA
  • [3] Prediction of comprehensive two-dimensional gas chromatographic separations - A theoretical and practical exercise
    Beens, J
    Tijssen, R
    Blomberg, J
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1998, 822 (02) : 233 - 251
  • [4] Simple, non-moving modulation interface for comprehensive two-dimensional gas chromatography
    Beens, J
    Adahchour, M
    Vreuls, RJJ
    van Altena, K
    Brinkman, UAT
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2001, 919 (01) : 127 - 132
  • [5] Dallüge J, 2002, J SEP SCI, V25, P201, DOI 10.1002/1615-9314(20020301)25:4<201::AID-JSSC201>3.0.CO
  • [6] 2-B
  • [7] VISCOSITY OF GASES USED AS THE MOBILE PHASE IN GAS-CHROMATOGRAPHY
    ETTRE, LS
    [J]. CHROMATOGRAPHIA, 1984, 18 (05) : 243 - 248
  • [8] A NEW METHOD FOR PREDICTION OF BINARY GAS-PHASE DIFFUSION COEFFECIENTS
    FULLER, EN
    SCHETTLE, PD
    GIDDINGS, JC
    [J]. INDUSTRIAL AND ENGINEERING CHEMISTRY, 1966, 58 (05): : 19 - +
  • [9] THE MASS LOADABILITY OF VARIOUS STATIONARY PHASES IN GAS-CHROMATOGRAPHY
    GHIJSEN, RT
    POPPE, H
    KRAAK, JC
    DUYSTERS, PPE
    [J]. CHROMATOGRAPHIA, 1989, 27 (1-2) : 60 - 66
  • [10] CONCEPTS AND COMPARISONS IN MULTIDIMENSIONAL SEPARATION
    GIDDINGS, JC
    [J]. JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (05): : 319 - 323