Operation of a fault tolerant PM drive for an aerospace fuel pump application

被引:85
作者
Haylock, JA
Mecrow, BC
Jack, AG
Atkinson, DJ
机构
[1] BOC Edwards, Eastbourne BN22 9BA, England
[2] Univ Newcastle Upon Tyne, Dept Elect & Elect Engn, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
来源
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS | 1998年 / 145卷 / 05期
关键词
fault tolerant permanent magnet drive; current controller; fault detection;
D O I
10.1049/ip-epa:19982164
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper discusses the design of a fault tolerant permanent magnet drive based on a 16 kW, 13000 rev/min aircraft fuel pump specification. A 'proof of concept' demonstrator has been built to this design and key parameters measured on the demonstrator drive are given. A novel current controller with near optimal transient performance is developed to enable precise shaping of the phase currents at high shaft speeds. A list of the most likely electrical faults is considered. Fault detection add identification schemes are developed for rapid detection of turn to turn faults and power device short circuit faults. Post fault control strategies are described which enable the drive to continue to operate indefinitely in the presence of each fault. Finally, results show the initially healthy drive operating up to, through and beyond the introduction of two of the more serious faults.
引用
收藏
页码:441 / 448
页数:8
相关论文
共 7 条