Radiation tolerance of the rat spinal cord after single and split doses of photons and carbon ions

被引:40
作者
Debus, J
Scholz, M
Haberer, T
Peschke, P
Jäkel, O
Karger, CP
Wannenmacher, M
机构
[1] German Canc Res Ctr, Dept Radiat Oncol, D-69120 Heidelberg, Germany
[2] Gesell Schwerionenforsch, Dept Biophys, Darmstadt, Germany
[3] DKFZ, German Canc Res Ctr, Dept Med Phys, Heidelberg, Germany
[4] Univ Heidelberg, Dept Clin Radiol, Heidelberg, Germany
关键词
LATE FUNCTIONAL-CHANGES; CENTRAL-NERVOUS-SYSTEM; FOLLOW-UP TIME; SKULL BASE; X-RAYS; RESPONSE CURVES; HEAVY-IONS; IRRADIATION; MYELOPATHY; RADIOTHERAPY;
D O I
10.1667/3063
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The sensitivity of the rat spinal cord to single and split doses of radiation and the resulting relative biological effectiveness (RBE) were determined for carbon-ion irradiations (C-12) in the plateau and Bragg-peak regions. The cranial part of the cervical and thoracic spinal cords of 180 rats were irradiated with one or two fractions of C-12 ions or photons, respectively. Dose-response curves for the end point symptomatic myelopathy were established, and the resulting values for the ED50 (dose for 50% complication probability) were used to determine the RBEs. A median latency for myelopathy of 167 days (range, 121-288 days) was found. The ED50 values were 17.1 +/- 0.8 Gy, 24.9 +/- 0.7 Gy (one and two fractions, C-12 plateau) and 13.9 +/- 0.8, 15.8 +/- 0.7 Gy (one and two fractions, C-12 Bragg peak), respectively. For photons we obtained ED50 values of 24.5 +/- 0.8 Gy for single doses and 34.2 +/- 0.7 Gy when two fractions were applied. The corresponding RBEs were 1.43 +/- 0.08, 1.37 +/- 0.12 (one and two fractions, C-12 plateau) and 1.76 +/- 0.05, 2.16 +/- 0.11 (one and two fractions, C-12 Bragg peak), respectively. Hematoxylin and eosin staining revealed necrosis of the white matter in the spinal cord in all symptomatic animals. In summary, from one- and two-fraction photon, C-12 plateau and Bragg-peak irradiation of the rat spinal cord, we have established RBEs as well as the individual ED50's. From the latter there is a clear indication of repair processes for fractionated photons and C-12 plateau ions which are significantly reduced by using Bragg-peak ions. Additional studies are being carried with 6 and 18 fractions to further refine and define the RBE and ED50 values and estimate the alpha/beta ratios. (C) 2003 by Radiation Research Society.
引用
收藏
页码:536 / 542
页数:7
相关论文
共 45 条
[1]   THE TOLERANCE OF PRIMATE SPINAL-CORD TO REIRRADIATION [J].
ANG, KK ;
PRICE, RE ;
STEPHENS, LC ;
JIANG, GL ;
FENG, Y ;
SCHULTHEISS, TE ;
PETERS, LJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 25 (03) :459-464
[2]   INHALATION ANESTHESIA IN EXPERIMENTAL RADIOTHERAPY - A RELIABLE AND TIME-SAVING SYSTEM FOR MULTIFRACTIONATION STUDIES IN A CLINICAL DEPARTMENT [J].
ANG, KK ;
VANDERKOGEL, AJ ;
VANDERSCHUEREN, E .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1982, 8 (01) :145-148
[3]   EXPERIENCE IN CHARGED-PARTICLE IRRADIATION OF TUMORS OF THE SKULL BASE - 1977-1992 [J].
CASTRO, JR ;
LINSTADT, DE ;
BAHARY, JP ;
PETTI, PL ;
DAFTARI, I ;
COLLIER, JM ;
GUTIN, PH ;
GAUGER, G ;
PHILLIPS, TL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 29 (04) :647-655
[4]  
Debus J, 2000, STRAHLENTHER ONKOL, V176, P211, DOI 10.1007/s000660050002
[5]   EFFECT OF PENTOBARBITAL-ANESTHESIA ON THE RADIOSENSITIVITY OF 4 MOUSE-TUMORS [J].
DENEKAMP, J ;
TERRY, NHA ;
SHELDON, PW ;
CHU, AM .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1979, 35 (03) :277-280
[6]   TOLERANCE OF NORMAL TISSUE TO THERAPEUTIC IRRADIATION [J].
EMAMI, B ;
LYMAN, J ;
BROWN, A ;
COIA, L ;
GOITEIN, M ;
MUNZENRIDER, JE ;
SHANK, B ;
SOLIN, LJ ;
WESSON, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :109-122
[7]   RELATIONSHIP BETWEEN DOSE AND THE LATENT PERIOD FOR RADIATION MYELOPATHY IN RATS [J].
GERACI, JP ;
MARIANO, MS .
RADIATION RESEARCH, 1994, 140 (03) :340-346
[8]   MAGNETIC SCANNING SYSTEM FOR HEAVY-ION THERAPY [J].
HABERER, T ;
BECHER, W ;
SCHARDT, D ;
KRAFT, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 330 (1-2) :296-305
[9]   THE INFLUENCE OF FIELD SIZE ON THE LATE TOLERANCE OF THE RAT SPINAL-CORD TO SINGLE DOSES OF X-RAYS [J].
HOPEWELL, JW ;
MORRIS, AD ;
DIXONBROWN, A .
BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (719) :1099-1108
[10]  
JEREMIC B, 1991, CANCER-AM CANCER SOC, V68, P2138, DOI 10.1002/1097-0142(19911115)68:10<2138::AID-CNCR2820681009>3.0.CO