Automated continuous positive airway pressure titration for obstructive sleep apnea syndrome

被引:158
作者
Teschler, H [1 ]
BerthonJones, M [1 ]
Thompson, AB [1 ]
Henkel, A [1 ]
Henry, J [1 ]
Konietzko, N [1 ]
机构
[1] RESCARE LTD,SYDNEY,NSW,AUSTRALIA
关键词
D O I
10.1164/ajrccm.154.3.8810613
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
This study tested the effectiveness of the AutoSet(TM) self-titrating nasal continuous positive airway pressure (nCPAP) system in treating obstructive sleep apnea (OSA), and choosing a suitable pressure for subsequent conventional fixed-pressure nCPAP therapy. Twenty-one adult men with untreated OSA were studied with full polysomnography on each of four nights: diagnostic, manual and AutoSet nCPAP titration (in random order), and conventional fixed-pressure nCPAP at the pressure recommended by the AutoSet titration. Titration was satisfactorily performed in 20 of 21 subjects, Severe mask leak prevented automated titration in one subject and caused transient unnecessary increases in pressure in three subjects. In the 20 subjects, respiratory disturbance index (RDI) was 60.3 +/- 5.7 events/h (mean +/- SEM) on the diagnostic night. RDI was lower with manual titration (10.1 +/- 3.0, p < 0.001), and lower still with AutoSet (2.8 +/- 0.9, p < 0.01) and fixed pressure (2.5 +/- 0.7, p = ns versus AutoSet) nCPAP. There were similar changes in the arousal index, which was 52.7 +/- 4.5 events/h on the diagnostic night, 14.2 +/- 2.4 with manual titration and 8.9 +/- 0.9 with AutoSet titration, and 9.5 +/- 1.0 on the night of conventional fixed-pressure CPAP (p < 0.001 versus diagnostic). We conclude that the AutoSet system is suitable for automated nCPAP pressure titration.
引用
收藏
页码:734 / 740
页数:7
相关论文
共 19 条
[1]   FEASIBILITY OF A SELF-SETTING CPAP MACHINE [J].
BERTHONJONES, M .
SLEEP, 1993, 16 (08) :S120-S123
[2]  
BERTHONJONES M, 1994, P 4 WORLD C SLEEP AP, pA532
[3]  
BURKE JR, 1994, P 4 WORLD C SLEEP AP, pA585
[4]   FLOW LIMITATION AS A NONINVASIVE ASSESSMENT OF RESIDUAL UPPER-AIRWAY RESISTANCE DURING CONTINUOUS POSITIVE AIRWAY PRESSURE THERAPY OF OBSTRUCTIVE SLEEP-APNEA [J].
CONDOS, R ;
NORMAN, RG ;
KRISHNASAMY, I ;
PEDUZZI, N ;
GOLDRING, RM ;
RAPOPORT, DM .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 150 (02) :475-480
[5]  
GUILLEMINAULT C, 1991, SLEEP RES, V20, P250
[6]   PREDICTING NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE [J].
HOFFSTEIN, V ;
MATEIKA, S .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1994, 150 (02) :486-488
[7]   TREATMENT OF OBSTRUCTIVE SLEEP-APNEA WITH NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE - PATIENT COMPLIANCE, PERCEPTION OF BENEFITS, AND SIDE-EFFECTS [J].
HOFFSTEIN, V ;
VINER, S ;
MATEIKA, S ;
CONWAY, J .
AMERICAN REVIEW OF RESPIRATORY DISEASE, 1992, 145 (04) :841-845
[8]   UPPER AIRWAY CLOSING PRESSURES IN SNORERS [J].
ISSA, FG ;
SULLIVAN, CE .
JOURNAL OF APPLIED PHYSIOLOGY, 1984, 57 (02) :528-535
[9]   TREATMENT OF OBSTRUCTIVE SLEEP-APNEA SYNDROME WITH NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE [J].
MCEVOY, RD ;
THORNTON, AT .
SLEEP, 1984, 7 (04) :313-325
[10]   DEVELOPMENT AND APPLICATION OF AUTOMATIC NASAL CPAP CALIBRATION PROCEDURES FOR USE IN THE UNSUPERVISED HOME-ENVIRONMENT [J].
MILES, LE ;
BUSCHEK, GD ;
MCCLINTOCK, DP ;
MILES, SC ;
NARVIOS, LR ;
WANG, YX .
SLEEP, 1993, 16 (08) :S118-S119