Behaviour of precast concrete floor slabs exposed to standardised fires

被引:37
作者
Cooke, GME [1 ]
机构
[1] City Univ London, Dept Civil Engn, London EC1V 0HB, England
关键词
floor slabs; concrete; standard fire tests; thermal response; structural response;
D O I
10.1016/S0379-7112(01)00005-4
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper quantifies the thermal movements of 14 simply supported precast reinforced concrete floor slabs of 4.5 m span and 900 mm width exposed to two standardised heating regimes used in fire resistance furnace tests. The tests were designed to show the effect of varying the slab thickness, type of concrete, imposed load, soffit protection and nature of fire exposure on the mid-span flexural deflection and axial movements of the slab ends. Measured deflections showed that during the 90 min design period of fire resistance thermal bowing was dominant and the effect of the 1.5 kN/m(2) design imposed load was small. The NPD hydrocarbon fire exposure caused a doubling of the flexural deflections achieved using the standard BS 476: Part 8 (now Part 20) fire exposure in the first 20 min of exposure. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:459 / 475
页数:17
相关论文
共 5 条
[1]  
[Anonymous], 8110 BS BRIT STAND I
[2]  
*BRIT STAND I, 2001, 199312 DD ENV BRIT S
[3]  
COOKE GME, 1988, 2188 IP BUILD RES ES
[4]  
HOLMES M, 1982, STRUCT ENG-B, V60, P7
[5]  
MORRIS WA, 1988, 128 BR BRE