Three-dimensional method for comparing in vivo interventional MR images of thermally ablated tissue with tissue response

被引:29
作者
Breen, MS
Lancaster, TL
Lazebnik, RS
Nour, SG
Lewin, JS
Wilson, DL
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Sch Med, Cleveland, OH USA
[3] Cairo Univ Hosp, Dept Radiol, Cairo, Egypt
[4] Univ Hosp Cleveland, Dept Radiol, Cleveland, OH 44106 USA
关键词
image registration; magnetic resonance imaging (MRI); interventional imaging; thermal ablation; histology; medical imaging;
D O I
10.1002/jmri.10324
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the ability of magnetic resonance (MR) to monitor radio-frequency (RF) ablation treatments by comparing MR images of thermal lesions to histologically assayed cellular damage. We developed a new methodology using three-dimensional registration for making spatial correlations. Materials and Methods: A low-field, open MRI system was used to guide an ablation probe into rabbit thigh muscle and acquire MR volumes after ablation. After fixation, we sliced and photographed the tissue at 3-mm intervals, using a specially designed apparatus, to obtain a volume of tissue images. Histologic samples were digitized using a video microscopy system. For our three-dimensional registration method, we used the tissue images as the reference, and registered histology and MR images to them using two different computer alignment steps. First, the MR volume was aligned to the volume of tissue images by registering needle fiducials placed near the tissue of interest. Second, we registered the histology images with the tissue images using a two-dimensional warping technique that aligned internal features and the outside boundary of histology and tissue images. Results: The MR and, histology images were very well aligned, and registration accuracy, determined from displacement of needle fiducials, was 1.32 +/- 0.39 mm (mean +/- SD), which compared favorably to the MR voxel dimensions (0.70 mm in-plane and 3.0 mm thick). A preliminary comparison of MR and tissue response showed that the region inside the elliptical hyperintense rim in MR closely corresponds to the region of necrosis as established by histology, with a mean absolute distance between MR and histology boundaries of 1.17 mm, slightly smaller than the mean registration error. The MR region slightly overestimated the region of necrosis, with a mean signed distance between boundaries of 0.85 mm. Conclusion: Our results suggest that our methodology can be used to achieve three-dimensional registration of histology and in vivo MR images. In MR lesion images, the inner border of the hyperintense region corresponds to the border of irreversible cell damage. This is good evidence that during RF ablation treatments, fMRI lesion images can be used for real-time feedback.
引用
收藏
页码:90 / 102
页数:13
相关论文
共 20 条
[1]  
BAROLDI G, 2001, CARDIOVASC PATHOL, P202
[2]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[3]   MR monitoring of MR-guided radiofrequency thermal ablation of normal liver in an animal model [J].
Boaz, TL ;
Lewin, JS ;
Chung, YC ;
Duerk, JL ;
Clampitt, ME ;
Haaga, JR .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (01) :64-69
[4]  
Chen L, 2001, J MAGN RESON IMAGING, V13, P23, DOI 10.1002/1522-2586(200101)13:1<23::AID-JMRI1004>3.0.CO
[5]  
2-G
[6]  
CUTTS A, 1988, J ANAT, V160, P75
[7]   MR IMAGING OF LASER-TISSUE INTERACTIONS [J].
JOLESZ, FA ;
BLEIER, AR ;
JAKAB, P ;
RUENZEL, PW ;
HUTTL, K ;
JAKO, GJ .
RADIOLOGY, 1988, 168 (01) :249-253
[8]  
LANCASTER TL, IN PRESS ANN BIOMED
[9]  
LAZEBNIK RS, IN PRESS IEEE T MED
[10]  
Lee Z, 2001, J NUCL MED, V42, p294P