Investigations on plasma-polymer-coated SAW and STW resonators for chemical gas-sensing applications

被引:34
作者
Avramov, ID [1 ]
Kurosawa, S
Rapp, M
Krawczak, P
Radeva, EI
机构
[1] Bulgarian Acad Sci, Inst Solid State Phys, BU-1784 Sofia, Bulgaria
[2] Natl Inst Mat & Chem Res, Dept Polymer Phys, Ultrathin Film Grp, Tsukuba, Ibaraki 3058565, Japan
[3] Res Ctr Karlsruhe, Inst Instrumental Anal, D-76344 Eggenstein Leopoldshafen, Germany
关键词
films; gas detectors; plasma; polymers; surface acoustic wave resonators;
D O I
10.1109/22.915471
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Results from gas probing with various analyte vapors on high-Q low-loss surface transverse wave (STW) and surface acoustic wave (SAW) resonators coated with thin plasma-polymer films of hexamethyldisiloxane (HMDSO), styrene, and allyl alcohol at different polymerization conditions are presented in this paper. At the same acoustic wavelength of 7.22 mum and identical film thicknesses, HMDSO-coated STW devices feature substantially higher relative sensitivities to all analytes compared to their SAW counterparts. When operated in a microwave oscillator loop, plasma-poly-styrene and allyl-alcohol-coated STW devices generate strong sensor signals, even at low analyte concentrations, retaining an oscillator short-term stability in the 1 times 10(-9)/s to 1 x 10(-8)/s range. A 250-kHz sensor signal with 7 x 10(-9)/s stability was obtained from a styrene coated 700-MHz STW resonator oscillator at a 1400 parts per million concentration of xylene vapor, which results in a measurement resolution of less than 40 parts per billion for xylene in the ambient air. It is shown that, with respect to sensitivity and stability over long probing periods, plasma-polymer Rims may become a serious competitor to the more or less unstable soft polymer coatings currently used in SAW-based gas sensors for applications in wireless systems for environmental control and protection.
引用
收藏
页码:827 / 837
页数:11
相关论文
共 28 条
  • [1] Avramov I. D., 2000, International Journal of High Speed Electronics and Systems, V10, P735, DOI 10.1142/S0129156400000635
  • [2] Comparative studies on polymer coated SAW and STW resonators for chemical gas sensor applications
    Avramov, ID
    Rapp, M
    Voigt, A
    Stahl, U
    Dirschka, M
    [J]. PROCEEDINGS OF THE 2000 IEEE/EIA INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM & EXHIBITION, 2000, : 58 - 65
  • [3] BAER RL, 1992, ULTRASON, P293, DOI 10.1109/ULTSYM.1992.275993
  • [4] BALLANTINE DS, 1989, ACS SYM SER, V403, P222
  • [5] UV crosslinked polysiloxanes as new coating materials for SAW devices with high long-term stability
    Barie, N
    Rapp, M
    Ache, HJ
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1998, 46 (02) : 97 - 103
  • [6] Passive remote sensing for temperature and pressure using SAW resonator devices
    Buff, W
    Klett, S
    Rusko, M
    Ehrenpfordt, J
    Goroll, M
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (05) : 1388 - 1392
  • [7] SENSOR MATERIALS FOR SOLVENT VAPOR DETECTION - DONOR-ACCEPTOR AND HOST-GUEST INTERACTIONS
    DICKERT, FL
    HAUNSCHILD, A
    [J]. ADVANCED MATERIALS, 1993, 5 (12) : 887 - 895
  • [8] DICKERT FL, 1996, ADV MAT, V8
  • [9] Performance of an embedded SAW sensor for filter bed monitor and the development of a wireless monitoring prototype system
    Dominguez, DD
    McGill, RA
    Chung, R
    Nguyen, V
    [J]. PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM, 1998, : 602 - 607
  • [10] Frye G.C., 1991, P IEEE TRANSDUCERS, P566