Materials for multifunctional balloon catheters with capabilities in cardiac electrophysiological mapping and ablation therapy

被引:406
作者
Kim, Dae-Hyeong [1 ,2 ]
Lu, Nanshu [1 ,2 ]
Ghaffari, Roozbeh [3 ]
Kim, Yun-Soung [1 ,2 ]
Lee, Stephen P. [3 ]
Xu, Lizhi [1 ,2 ]
Wu, Jian [4 ,5 ]
Kim, Rak-Hwan [1 ,2 ]
Song, Jizhou [6 ]
Liu, Zhuangjian [7 ]
Viventi, Jonathan [8 ]
de Graff, Bassel [3 ]
Elolampi, Brian [3 ]
Mansour, Moussa [9 ]
Slepian, Marvin J. [10 ]
Hwang, Sukwon [1 ,2 ]
Moss, Joshua D. [11 ]
Won, Sang-Min [1 ,2 ]
Huang, Younggang [4 ,5 ]
Litt, Brian [8 ,12 ]
Rogers, John A. [1 ,2 ]
机构
[1] Univ Illinois, Beckman Inst Adv Sci & Technol, Dept Mat Sci & Engn, Urbana, IL 61801 USA
[2] Univ Illinois, Frederick Seitz Mat Res Lab, Urbana, IL 61801 USA
[3] MC10 Inc, Cambridge, MA 02140 USA
[4] Northwestern Univ, Dept Mech Engn, Evanston, IL 60208 USA
[5] Northwestern Univ, Dept Civil & Environm Engn, Evanston, IL 60208 USA
[6] Univ Miami, Dept Mech & Aerosp Engn, Coral Gables, FL 33146 USA
[7] Inst High Performance Comp, Singapore 138632, Singapore
[8] Univ Penn, Dept Bioengn, Philadelphia, PA 19104 USA
[9] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Boston, MA 02114 USA
[10] Univ Arizona, Sarver Heart Ctr, Tucson, AZ 85724 USA
[11] Hosp Univ Penn, Dept Cardiol, Philadelphia, PA 19104 USA
[12] Hosp Univ Penn, Dept Neurol, Philadelphia, PA 19104 USA
基金
美国国家科学基金会;
关键词
PULMONARY VEIN ISOLATION; PAROXYSMAL ATRIAL-FIBRILLATION; OF-THE-ART; RADIOFREQUENCY ABLATION; TACTILE SENSOR; BIOCOMPATIBILITY; SEPTOSTOMY; EXPERIENCE; DESIGNS; MATRIX;
D O I
10.1038/NMAT2971
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Developing advanced surgical tools for minimally invasive procedures represents an activity of central importance to improving human health. A key challenge is in establishing biocompatible interfaces between the classes of semiconductor device and sensor technologies that might be most useful in this context and the soft, curvilinear surfaces of the body. This paper describes a solution based on materials that integrate directly with the thin elastic membranes of otherwise conventional balloon catheters, to provide diverse, multimodal functionality suitable for clinical use. As examples, we present sensors for measuring temperature, flow, tactile, optical and electrophysiological data, together with radiofrequency electrodes for controlled, local ablation of tissue. Use of such 'instrumented' balloon catheters in live animal models illustrates their operation, as well as their specific utility in cardiac ablation therapy. The same concepts can be applied to other substrates of interest, such as surgical gloves.
引用
收藏
页码:316 / 323
页数:8
相关论文
共 39 条
[1]  
ALIOT EM, 2007, EUROPACE, V9, P335
[2]   Hemocompatibility, biocompatibility, inflammatory and in vivo studies of primary reference materials low-density polyethylene and polydimethylsiloxane:: A review [J].
Bélanger, MC ;
Marois, Y .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 2001, 58 (05) :467-477
[3]   Theoretical modeling for radiofrequency ablation: state-of-the-art and challenges for the future [J].
Berjano, Enrique J. .
BIOMEDICAL ENGINEERING ONLINE, 2006, 5 (1)
[4]   Treatment of Atrial Fibrillation With Antiarrhythmic Drugs or Radiofrequency Ablation Two Systematic Literature Reviews and Meta-Analyses [J].
Calkins, Hugh ;
Reynolds, Matthew R. ;
Spector, Peter ;
Sondhi, Manu ;
Xu, Yingxin ;
Martin, Amber ;
Williams, Catherine J. ;
Sledge, Isabella .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (04) :349-U49
[5]  
CHUN KR, 2009, J CARDIOVASC ELECTR, V30, P699
[6]   The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre study [J].
Chun, Kyoung-Ryul Julian ;
Schmidt, Boris ;
Metzner, Andreas ;
Tilz, Roland ;
Zerm, Thomas ;
Koester, Ilka ;
Fuernkranz, Alexander ;
Koektuerk, Buelent ;
Konstantinidou, Melanie ;
Antz, Matthias ;
Ouyang, Feifan ;
Kuck, Karl Heinz .
EUROPEAN HEART JOURNAL, 2009, 30 (06) :699-709
[7]   A micromachined piezoelectric tactile sensor for an endoscopic grasper - Theory, fabrication and experiments [J].
Dargahi, J ;
Parameswaran, M ;
Payandeh, S .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2000, 9 (03) :329-335
[8]   State-of-the-art and emerging technologies for atrial fibrillation ablation [J].
Dewire, Jane ;
Calkins, Hugh .
NATURE REVIEWS CARDIOLOGY, 2010, 7 (03) :129-138
[9]   Relationship Between Catheter Forces, Lesion Characteristics, "Popping," and Char Formation: Experience with Robotic Navigation System [J].
Di Biase, Luigi ;
Natale, Andrea ;
Barrett, Conor ;
Tan, Carmela ;
Elayi, Claude S. ;
Ching, Chi Keong ;
Wang, Paul ;
Al-Ahmad, Amin ;
Arruda, Mauricio ;
Burkhardt, J. David ;
Wisnoskey, Brian J. ;
Chowdhury, Punam ;
De Marco, Shari ;
Armaganijan, Luciana ;
Litwak, Kenneth N. ;
Schweikert, Robert A. ;
Cummings, Jennifer E. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (04) :436-440
[10]   Development of polyimide flexible tactile sensor skin [J].
Engel, J ;
Chen, J ;
Liu, C .
JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2003, 13 (03) :359-366