Direct bacterial identification from positive BacT/Alert blood cultures using MicroScan overnight and rapid panels

被引:20
作者
Waites, KB
Brookings, ES
Moser, SA
Zimmer, BL
机构
[1] Univ Alabama, Dept Pathol, Birmingham, AL 35233 USA
[2] Dade MicroScan Inc, W Sacramento, CA USA
关键词
D O I
10.1016/S0732-8893(98)00058-3
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Studies were conducted on a method of direct inoculation of MicroScan overnight and rapid panels from positive BacT/Alert blood culture bottles containing standard aerobic media to determine the correlation with inoculation of the corresponding panels with a standardized bacterial suspension? obtained following subculture to agar. For Gram-negative organisms, 122 of 127 (96%) overnight panels and 85 of 118 (72%) rapid panels showed complete agreement with the standard method for species identification. Highest concordance (99%) occurred with Enterobacteriaceae inoculated directly into overnight panels. For Gram-positive organisms, 70 of 85 (82%) overnight panels and 45 of 86 (52%) rapid panels showed complete agreement. These findings suggest that direct inoculation? of Gram-negative overnight MicroScan panels yields results most comparable to standard methods when Enterobacteriaceae are detected and allows reporting of results 18 to 24 h sooner. Direct inoculation of Gram-positive overnight or rapid panels and Gram-negative rapid panels from tills blood culture medium did not yield acceptable identification results and is not recommended. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 20 条
[1]   RAPID DETECTION AND IDENTIFICATION OF MICROORGANISMS FROM BLOOD CULTURES [J].
CHORNY, JA ;
WILSON, ML .
CLINICS IN LABORATORY MEDICINE, 1994, 14 (01) :181-195
[2]  
DEVITT KA, 1995, 9K GEN M AM SOC MICR, P60
[3]   DIRECT IDENTIFICATION AND SUSCEPTIBILITY TESTING OF GRAM-NEGATIVE BACILLI FROM BACTEC BOTTLES BY USE OF THE MS-2 SYSTEM WITH UPDATED BACTERIAL IDENTIFICATION SOFTWARE [J].
DIPERSIO, JR ;
FICORILLI, SM ;
VARGA, FJ .
JOURNAL OF CLINICAL MICROBIOLOGY, 1984, 20 (06) :1202-1204
[4]   CLINICAL IMPACT OF RAPID IN-VITRO SUSCEPTIBILITY TESTING AND BACTERIAL IDENTIFICATION [J].
DOERN, GV ;
VAUTOUR, R ;
GAUDET, M ;
LEVY, B .
JOURNAL OF CLINICAL MICROBIOLOGY, 1994, 32 (07) :1757-1762
[5]  
EDBERG SC, 1975, J CLIN MICROBIOL, V2, P469
[6]   EVALUATION OF 2 COMMERCIAL SYSTEMS FOR IDENTIFICATION OF COAGULASE-NEGATIVE STAPHYLOCOCCI TO SPECIES LEVEL [J].
GRANT, CE ;
SEWELL, DL ;
PFALLER, M ;
BUMGARDNER, RV ;
WILLIAMS, JA .
DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 1994, 18 (01) :1-5
[7]   EVALUATION OF RAPID IDENTIFICATION OF GRAM-POSITIVE COCCI IN POSITIVE BLOOD CULTURES BY USE OF THE AUTOMICROBIC SYSTEM GRAM-POSITIVE IDENTIFICATION CARD [J].
HAMOUDI, AC ;
MARCON, MJ ;
CANNON, HJ .
JOURNAL OF CLINICAL MICROBIOLOGY, 1984, 20 (02) :171-174
[8]   IDENTIFICATION OF STAPHYLOCOCCUS SPECIES AND SUBSPECIES WITH THE MICROSCAN POS ID AND RAPID POS ID PANEL SYSTEMS [J].
KLOOS, WE ;
GEORGE, CG .
JOURNAL OF CLINICAL MICROBIOLOGY, 1991, 29 (04) :738-744
[9]   COMPARISON OF 4 RAPID METHODS FOR IDENTIFICATION OF ENTEROBACTERIACEAE FROM BLOOD CULTURES [J].
MALLOY, PJ ;
DUCATE, MJ ;
SCHRECKENBERGER, PC .
JOURNAL OF CLINICAL MICROBIOLOGY, 1983, 17 (03) :493-499
[10]   THE MICROSCAN WALKAWAY DIAGNOSTIC MICROBIOLOGY SYSTEM - AN EVALUATION [J].
MCGREGOR, A ;
SCHIO, F ;
BEATON, S ;
BOULTON, V ;
PERMAN, M ;
GILBERT, G .
PATHOLOGY, 1995, 27 (02) :172-176