Gated SPET myocardial perfusion acquisition within 5 minutes using focussing collimators and a three-head gamma camera

被引:10
作者
Everaert, H [1 ]
Vanhove, C [1 ]
Franken, PR [1 ]
机构
[1] Free Univ Brussels, Acad Hosp, Div Nucl Med, B-1090 Brussels, Belgium
关键词
cardiofocal collimators; gated single-photon emission tomography; myocardial perfusion;
D O I
10.1007/s002590050259
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Short acquisition protocols for gated single-photon emission tomography (SPET) myocardial perfusion imaging are desirable for sequential imaging to evaluate the myocardial response during pharmacological intervention. In this study a less than 5 min gated SPET acquisition protocol is proposed. Perfusion characteristics (defect severity) and left ventricular ejection fraction Introduction (LVEF), end-diastolic and end-systolic volumes (EDV, ESV), wall motion (WM) and wall thickening (WT) were calculated, checked for reproducibility and compared with data obtained using a standard gated SPET acquisition protocol. Gated SPET images were recorded in 20 patients starting 60 min after the administration of 925 MBq technetium-99m tetrofosmin at rest. The 5 min gated SPET studies were acquired with a three-head camera equipped with Cardiofocal collimators. This protocol was repeated twice. In addition gated SPET studies were acquired according to a standard protocol using parallel-hole collimators. The severity of perfusion defects was quantified on polar maps using the non-gated image data and a normal database. LVEF EDV, ESV, WM and WT were calculated from the gated images. The agreement between 5-min and standard gated SPET acquisitions was excellent for all investigated parameters. The reproducibility of repeated 5-min acquisitions for the quantification of perfusion defect severity was excellent (r=0.97). The agreement for segmental WT scores between repeated 5-min gated SPET acquisitions was good: kappa=0.71; major differences in segmental classification were observed in 2.5%. For WM a good agreement was found for segments with a tracer uptake greater than or equal to 30% of the maximum: kappa=0.65, major differences =7.7%. Excellent reproducibility was found for LVEF EDV and ESV measurements: r=0.97, 0.99 and 0.99, respectively. It is concluded that fast gated SPET perfusion studies acquired in less than 5 min yield accurate and reproducible measurements of myocardial perfusion and function (global and regional), In addition the results obtained with the 5-min gated SPET protocol correlate well with those obtained using a standard acquisition protocol.
引用
收藏
页码:587 / 593
页数:7
相关论文
共 11 条
[1]   Regional myocardial motion and thickening assessed at rest by ECG-gated Tc-99m-MIBI emission tomography and by magnetic resonance imaging [J].
Anagnostopoulos, C ;
Gunning, MG ;
Pennell, DJ ;
Laney, R ;
Proukakis, H ;
Underwood, SR .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1996, 23 (08) :909-916
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
BUDINGER TF, 1980, J NUCL MED, V21, P579
[4]   GATED TC-99M SESTAMIBI FOR SIMULTANEOUS ASSESSMENT OF STRESS MYOCARDIAL PERFUSION, POSTEXERCISE REGIONAL VENTRICULAR-FUNCTION AND MYOCARDIAL VIABILITY - CORRELATION WITH ECHOCARDIOGRAPHY AND REST TL-201 SCINTIGRAPHY [J].
CHUA, T ;
KIAT, H ;
GERMANO, G ;
MAURER, G ;
VANTRAIN, K ;
FRIEDMAN, J ;
BERMAN, D .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (05) :1107-1114
[5]   Left ventricular ejection fraction and volumes from gated single photon emission tomographic myocardial perfusion images: Comparison between two algorithms working in three-dimensional space [J].
Everaert, H ;
Bossuyt, A ;
Franken, PR .
JOURNAL OF NUCLEAR CARDIOLOGY, 1997, 4 (06) :472-476
[6]  
Everaert H, 1998, EUR J NUCL MED, V25, P3
[7]  
Germano G, 1997, J NUCL MED, V38, P749
[8]  
GERMANO G, 1995, J NUCL MED, V36, P2138
[9]   Effect of the number of projections collected on quantitative perfusion and left ventricular ejection fraction measurements from gated myocardial perfusion single-photon emission computed tomographic images [J].
Germano, G ;
Kavanagh, PB ;
Berman, DS .
JOURNAL OF NUCLEAR CARDIOLOGY, 1996, 3 (05) :395-402
[10]  
GERMANO G, 1992, NUCLEAR CARDIOLOGY S, P77