An investigation of the toxicity of gadolinium based MRI contrast agents using neutron activation analysis

被引:68
作者
Bartolini, ME
Pekar, J
Chettle, DR
McNeill, F
Scott, A
Sykes, J
Prato, FS
Moran, GR [1 ]
机构
[1] McMaster Univ, Dept Med Phys & Appl Radiat Sci, Hamilton, ON, Canada
[2] Hamilton Hlth Sci, Cent Anim Facil, Hamilton, ON, Canada
[3] Lawson Hlth Res Inst, Imaging Div, London, ON, Canada
关键词
gadolinium; magnetic resonance imaging; contrast agents; toxicity; neutron activation analysis;
D O I
10.1016/S0730-725X(03)00081-X
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The toxicity of gadolinium (Gd) based MRI contrast agents, is based upon the amount of Gd that dissociates from its chelate and deposits in tissues. In this study, the toxicities of two contrast agents were tested using different injection strategies in two animal models. Following a bolus injection of 0.2 mmol/kg of Gd-DTPA in a pilot study with a single canine, Gd levels were as high as 2.05 +/- 0.17 ppm and 0.47 +/- 0.11 ppm 2 weeks post injection in the kidney and liver tissues, respectively. To evaluate the role that the injection strategy plays in toxicity, 0.8 mmol/kg of Gd-(HP-DO3A) was injected into rats, in a second study, via bolus and constant infusion techniques. Gd was only detected in the kidney in the bolus injected rats but in the lung as well in the constant infusion injected rats. Concentrations detected in the kidney for both strategies, were comparable within error: 1.37 +/- 0.46 ppm for the bolus and 1.24 +/- 0.39 ppm for the bolus/constant infusion strategy and 0.16 +/- 0.14 ppm in the lung for the constant infusion technique. The contrast infusion technique does not appear to present an increased risk of toxicity over the bolus technique except perhaps to a small degree in the lung. (C) 2003 Elsevier Inc. All rights reserved.
引用
收藏
页码:541 / 544
页数:4
相关论文
共 16 条
[1]  
BOUDREAU RJ, 1987, J NUCL MED, V28, P349
[2]   GADOLINIUM-DTPA AS A CONTRAST AGENT IN MRI - INITIAL CLINICAL-EXPERIENCE IN 20 PATIENTS [J].
CARR, DH ;
BROWN, J ;
BYDDER, GM ;
STEINER, RE ;
WEINMANN, HJ ;
SPECK, U ;
HALL, AS ;
YOUNG, IR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (02) :215-224
[3]   TABLE OF THE ISOTOPIC COMPOSITIONS OF THE ELEMENTS [J].
DEBIEVRE, P ;
TAYLOR, PDP .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 123 (02) :149-166
[4]   Measurement of the gadopentetate dimeglumine partition coefficient in human myocardium in vivo: Normal distribution and elevation in acute and chronic infarction [J].
Flacke, SJ ;
Fischer, SE ;
Lorenz, CH .
RADIOLOGY, 2001, 218 (03) :703-710
[5]  
GLASCOCK MD, 1988, RES REACTOR FACILITY, P3
[6]  
MORAN GR, 2001, IN PRESS MAGN RE JUN
[7]  
Pereira RS, 2000, MAGN RESON MATER PHY, V11, P104, DOI 10.1016/S1352-8661(00)00093-4
[8]  
PRATO FS, 1988, J NUCL MED, V29, P1683
[9]  
Shellock FG, 1999, J MAGN RESON IMAGING, V10, P477, DOI 10.1002/(SICI)1522-2586(199909)10:3<477::AID-JMRI33>3.3.CO
[10]  
2-5