Measurement of physiological concentrations of dapsone and its monoacetyl metabolite: A miniaturised assay for liquid or filter paper-absorbed samples

被引:4
作者
Mberu, EK
Muhia, DK
Minyiri, GO
Njonge, EW
Watkins, WM
机构
[1] KENYA GOVT MED RES CTR,NAIROBI,KENYA
[2] UNIV LIVERPOOL,DEPT PHARMACOL & THERAPEUT,LIVERPOOL L69 3BX,MERSEYSIDE,ENGLAND
[3] UNIV BRADFORD,DEPT BIOMED SCI,BRADFORD BD7 1DP,W YORKSHIRE,ENGLAND
来源
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS | 1996年 / 677卷 / 02期
基金
英国惠康基金;
关键词
dapsone; monoacetyldapsone;
D O I
10.1016/0378-4347(95)00510-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A modification of existing HPLC assay methods is described for the measurement of dapsone and monoacetyldapsone in 50-mu l samples of plasma and whole blood. This method, in particular the use of small sample volumes dried onto filter paper strips, is applicable to multi-sample clinical and pharmacokinetic studies in children with malaria, who are often anaemic, and where sample volume must be kept to a minimum. Basified samples were extracted into 5 mi of ethyl acetate-tert.-butylmethyl ether(1:1, v/v), chromatographed on a mu BondapaK C-18 10-mu m column with water-acetonitrile-glacial acetic acid (81:17.5:5, v/v) containing 2 g/l 1-octanesulphonic acid as the mobile phase and detected at 274 nm