Simultaneous high-throughput determination of clenbuterol, ambroxol and bromhexine in pharmaceutical formulations by HPLC with potentiometric detection

被引:72
作者
Bazylak, G
Nagels, LJ
机构
[1] Univ Antwerp, RUCA, Dept Chem, Fac Sci & Biomed, B-2020 Antwerp, Belgium
[2] Rydygier Med Univ, Fac Pharm, Dept Drug Chem, PL-85067 Bydgoszcz, Poland
关键词
potentiometric detection; HPLC; ambroxol; clenbuterol; mucolytic drugs;
D O I
10.1016/S0731-7085(03)00191-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Potentiometric detection of clenbuterol, ambroxol and bromhexine in marketed pharmaceuticals was described in six isocratic HPLC systems. The podant- and macrocyclic-type neutral ionophores, N,N,N',N'-tetracyclohexyl-oxybis(ophenyleneoxy)diacetamide (TOPA) and hexakis(2,3,6-tri-O-octyl)-alpha-cyclodextrin (OCD), were applied in poly(vinyl)chloride (PVC)-based liquid membrane electrodes. Both types of neutral ionophores improve the sensitivity for all mentioned drugs when compared with a tetrakis(p-chlorophenyl)borate (BOR)-based electrode as well as with single wavelength UV detection. Detection limits (SIN= 3) of 2.6 x 10(-10) mol l(-1) (injected concentration) for the highly hydrophobic bromhexine were achieved with the TOPA-based electrode and a cyano reversed-phase (RP)-HPLC with Uptisphere(R) UP5CN-25QS silica column (250 x 4.6 mm i.d.) eluted with acetonitrile (AcN) -ethanol -perchloric acid (1.66 mM) (60:2:38, v/v/v) (pH* 2.45). Comparable result was obtained with OCD-based electrodes and an XTerra(TM) RP 18 hybrid silica-polymer column eluted with AcN-phosphoric acid (20 mM) (25:75, v/v) (pH* 2.60). In the mobile phases containing 60-75% v/v AcN or methanol, stable and reproducible response of both types of neutral ionophore-based electrodes was observed for at least 3 days. The results of the validated procedure for reliable simultaneous determination of the drugs in fortified representative samples of pharmaceuticals were also presented. (C) 2003 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:887 / 903
页数:17
相关论文
共 70 条
[1]  
[Anonymous], SENS ACTUATORS B
[2]  
Argekar AP, 1998, JPC-J PLANAR CHROMAT, V11, P254
[3]   Potentiometric detection of exogenic beta-adrenergic substances in liquid chromatography [J].
Bazylak, G ;
Nagels, LJ .
JOURNAL OF CHROMATOGRAPHY A, 2002, 973 (1-2) :85-96
[4]   RAPID AND SENSITIVE DETERMINATION OF AMBROXOL IN HUMAN-PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BOTTERBLOM, MHA ;
JANSSEN, TJ ;
GUELEN, PJM ;
VREE, TB .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 421 (01) :211-215
[5]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF AMBROXOL IN PHARMACEUTICALS [J].
BRIZZI, V ;
PASETTI, U .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (01) :107-109
[6]   Designing multidrug-resistance modulators circumventing the reverse pH gradient in tumours [J].
Castaing, M ;
Loiseau, A ;
Dani, M .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 2001, 53 (07) :1021-1028
[7]  
Chlubek D, 2001, Ginekol Pol, V72, P804
[8]   DETERMINATION OF AMBROXOL IN BIOLOGICAL-MATERIAL BY GAS-CHROMATOGRAPHY WITH ELECTRON-CAPTURE DETECTION [J].
COLOMBO, L ;
MARCUCCI, F ;
MARINI, MG ;
PIERFEDERICI, P ;
MUSSINI, E .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1990, 530 (01) :141-147
[9]   Recent developments in the use and abuse of growth promoters [J].
Courtheyn, D ;
Le Bizec, B ;
Brambilla, G ;
De Brabander, HF ;
Cobbaert, E ;
de Wiele, AV ;
Vercammen, J ;
De Wasch, K .
ANALYTICA CHIMICA ACTA, 2002, 473 (1-2) :71-82
[10]  
Crommen J, 1983, J Pharm Biomed Anal, V1, P549, DOI 10.1016/0731-7085(83)80068-5