Clinical evaluation of the FloTrac/Nigileo™ system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery

被引:121
作者
Button, D.
Weibel, L.
Reuthebuch, O.
Genoni, M.
Zollinger, A.
Hofer, C. K.
机构
[1] Triemli City Hosp Zurich, Inst Anaesthesiol & Intens Care Med, CH-8063 Zurich, Switzerland
[2] Univ Zurich Hosp, Triemli City Hosp Zurich, Clin Cardiac Surg, Div Cardiac Surg, CH-8091 Zurich, Switzerland
关键词
heart; cardiac output; measurement techniques; cardiac ouput; thermodilution;
D O I
10.1093/bja/aem188
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Assessment of cardiac output (CO) by the FloTrac/Vigileo(TM) system may offer a less invasive means of determining the CO than either the pulmonary artery catheter (PAC) or the PiCCOplus(TM) system. The aim of this study was to compare CO measurements made using the FloTrac/Vigileo(TM) system with upgraded software (FCO, Edwards Lifesciences, Irvine CA, USA), the PiCCOplus(TM) system (PCO, Pulsion Medical Systems, Munich, Germany) and continuous CO monitoring using a PAC (CCO; Vigilance(TM) monitoring, Edwards Lifesciences, Irvine CA, USA) with intermittent pulmonary artery thermodilution (ICO). The study was conducted in patients undergoing elective cardiac surgery. Methods. Thirty-one patients with preserved left ventricular function were enrolled. CCO, FCO, and PCO were recorded in the perioperative period at six predefined time points after achieving stable haemodynamic conditions; ICO was determined from the mean of three bolus injections. Bland-Altman analysis was used to compare CCO, FCO, and PCO with ICO. Results. Bland-Altman analysis revealed a comparable mean bias and limits of agreement for all tested continuous CO monitoring devices using ICO as reference method. Agreement for all devices decreased in the postoperative period. Conclusion. The performance of the FloTrac/Vigileo(TM) system, the PiCCOplus(TM), and the Vigilance(TM) CCO monitoring for CO measurement were comparable when tested against intermittent thermodilution in patients undergoing elective cardiac surgery.
引用
收藏
页码:329 / 336
页数:8
相关论文
共 27 条
  • [1] [Anonymous], 2002, ANESTHESIOL CLIN N A
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] CONTINUOUS VERSUS INTERMITTENT CARDIAC-OUTPUT MEASUREMENT IN CARDIAC SURGICAL PATIENTS UNDERGOING HYPOTHERMIC CARDIOPULMONARY BYPASS
    BOTTIGER, BW
    RAUCH, H
    BOHRER, H
    MOTSCH, J
    SODER, M
    FLEISCHER, F
    MARTIN, E
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1995, 9 (04) : 405 - 411
  • [4] The effectiveness of right heart catheterization in the initial care of critically ill patients
    Connors, AF
    Speroff, T
    Dawson, NV
    Thomas, C
    Harrell, FE
    Wagner, D
    Desbiens, N
    Goldman, L
    Wu, AW
    Califf, RM
    Fulkerson, WJ
    Vidaillet, H
    Broste, S
    Bellamy, P
    Lynn, J
    Knaus, WA
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (11): : 889 - 897
  • [5] Della Rocca G, 2003, CAN J ANAESTH, V50, P707
  • [6] Cardiac index measurements during rapid preload changes: a comparison of pulmonary artery thermodilution with arterial pulse contour analysis
    Felbinger, TW
    Reuter, DA
    Eltzschig, HK
    Bayerlein, J
    Goetz, AE
    [J]. JOURNAL OF CLINICAL ANESTHESIA, 2005, 17 (04) : 241 - 248
  • [7] Frezza EE, 1998, AM SURGEON, V64, P127
  • [8] Gödje O, 2002, CRIT CARE MED, V30, P52
  • [9] Continuous cardiac output by femoral arterial thermodilution calibrated pulse contour analysis: Comparison with pulmonary arterial thermodilution
    Goedje, O
    Hoeke, K
    Lichtwarck-Aschoff, M
    Faltchauser, A
    Lamm, P
    Reichart, B
    [J]. CRITICAL CARE MEDICINE, 1999, 27 (11) : 2407 - 2412
  • [10] Guyatt G, 1991, J Intensive Care Med, V6, P91