Economic analysis of hybrid photovoltaic-diesel-battery power systems for residential loads in hot regions - A step to clean future

被引:156
作者
Shaahid, S. M. [1 ]
Elhadidy, M. A. [1 ]
机构
[1] King Fahd Univ Petr & Minerals, Engn Res Ctr, Res Inst, Dhahran 31261, Saudi Arabia
关键词
solar irradiance; PV modules; residential loads; battery; diesel generators; carbon emissions;
D O I
10.1016/j.rser.2006.07.013
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The growing concerns of global warming and depleting oil/gas reserves have made it inevitable to seek energy from renewable energy resources. Many nations are embarking on introduction of clean/renewable solar energy for displacement of oil-produced energy. Moreover, solar photovoltaic (PV)-diesel hybrid power generation system technology is an emerging energy option since it promises great deal of challenges and opportunities for developed and developing countries. The Kingdom of Saudi Arabia (K.S.A) being enriched with higher level of solar radiation, is a prospective candidate for deployment of solar PV systems. Literature indicates that commercial/residential buildings in K.S.A. consume about 10-45% of the total electric energy generated. The aim of this study is to analyze long-term solar radiation data of Dhahran (East-Coast, K.S.A.) to assess the techno-economic feasibility of utilizing hybrid PV-diesel-battery power systems to meet the load of a typical residential building (with annual electrical energy demand of 35,120 kWh). The monthly average daily solar global radiation ranges from 3.61 to 7.96 kwh/m(2). National Renewable Energy Laboratory's (NREL) Hybrid Optimization Model for Electric Renewable (HOMER) software has been employed to carry out the present study. The simulation results indicate that for a hybrid system composed of 4 kWp PV system together with 10 kW diesel system and a battery storage of 3 h of autonomy (equivalent to 3 h of average load), the PV penetration is 22%. The cost of generating energy (COE, US$/kWh) from the above hybrid system has been found to be 0.179 $/kWh (assuming diesel fuel price of 0.1 $/1). The study exhibits that for a given hybrid configuration, the operational hours of diesel generators decrease with increase in PV capacity. The investigation also examines the effect of PV/battery penetration on COE, operational hours of diesel gensets for a given hybrid system. Concurrently, attention is focussed on un-met load, excess electricity generation, fuel savings and reduction in carbon emissions (for different scenarios such as PV-diesel without storage, PV-diesel with storage, as compared to diesel-only situation), COE of different hybrid systems, cost of PV-diesel-battery systems, etc. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:488 / 503
页数:16
相关论文
共 31 条
[1]  
Ali S, 2001, 7 AR INT SOL EN C SH, P4
[2]  
[Anonymous], SOLAR TODAY
[3]  
[Anonymous], RENEWABLE ENERGY
[4]  
Bergey M., 1993, WIND ENERGY APPL TRA
[5]   ANALYSIS OF INTERRELATIONSHIPS BETWEEN PHOTOVOLTAIC POWER AND BATTERY STORAGE FOR ELECTRIC UTILITY LOAD MANAGEMENT [J].
CHOWDHURY, BH ;
RAHMAN, S .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1988, 3 (03) :900-907
[6]  
COIANTE D, 1996, SOL ENERGY, V57, P485, DOI DOI 10.1016/S0038-092X(96)00136-3
[7]   Parametric study of hybrid (wind plus solar plus diesel) power generating systems [J].
Elhadidy, M ;
Shaahid, SM .
RENEWABLE ENERGY, 2000, 21 (02) :129-139
[8]   EFFECT OF KUWAITS OIL-FIRE SMOKE CLOUD ON GLOBAL HORIZONTAL IRRADIANCE AT DHAHRAN, SAUDI-ARABIA [J].
ELHADIDY, MA ;
SHAAHID, SM .
SOLAR ENERGY, 1994, 52 (05) :439-446
[9]  
ELHADIDY MA, 1998, WORLD REN EN C 5 FLO
[10]  
ELHADIDY MA, 1999, INT J RENEWABLE ENER, P77