Ultrasound echogenicity in experimental venous thrombosis

被引:30
作者
Fowlkes, JB
Strieter, RM
Downing, LJ
Brown, SL
Saluja, A
Salles-Cunha, S
Kadell, AM
Wrobleski, SK
Wakefield, TW
机构
[1] Univ Michigan, Med Ctr, Vasc Surg Sect, Ann Arbor, MI USA
[2] Univ Michigan, Med Ctr, Dept Surg, Jobst Vasc Res Lab, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Med Ctr, Dept Radiol, Div Basic Radiol Sci, Ann Arbor, MI 48109 USA
[4] Univ Michigan, Med Ctr, Dept Internal Med, Ann Arbor, MI 48109 USA
[5] Jobst Vasc Ctr, Toledo, OH USA
关键词
ultrasound; B-mode; echogenicity; fibrin; rat; primate; inferior vena cava; ligation; balloon; occlusion;
D O I
10.1016/S0301-5629(98)00089-1
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This study characterizes the echogenicity of experimentally induced venous thrombosis. Venous duplex imaging (Diasonics Spectra) was performed of the rat (n 12) and primate (n 3) inferior vena cava (IVC). Thrombosis was induced by IVC ligation at the level of the renal veins (rat, baboon) or balloon occlusion (baboon) of the IVC at the renal vein and iliac vein bifurcation level. Sham-treated rats served as controls. B-mode images were stored for off-line computer analysis. Fixed depth gain control curves allowed for measuring gain-corrected echogenicity units over the NC in both a longitudinal and transverse orientation. In rat studies, thrombus was removed at time of euthanasia and dissolved, allowing for fibrin monomer determination using a chromogenic assay. Echogenicity values generally increased over time in both rat and primate studies. Significant differences between ligated and sham-treated rats were noted at each time paint measured (6 h, 2 days, and 6 days after IVC ligation) and fibrin monomer values correlated (p < 0.05) with echogenicity units. In primate studies, echogenicity values significantly were different from baseline values at all time points measured (6 h, 2 days, 6 days, and 13 days after thrombus induction). Duplex ultrasound can be used to quantitate thrombus echogenicity, which correlates to fibrin content. Such measurement may potentially allow for improved thrombus age determination and the noninvasive quantitation of thrombus progression/resolution. (C) 1998 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:1175 / 1182
页数:8
相关论文
共 12 条
[1]  
FELEPPA EJ, 1987, IEEE ENG MED BI 1218
[2]   THEORETICAL FRAMEWORK FOR SPECTRUM ANALYSIS IN ULTRASONIC TISSUE CHARACTERIZATION [J].
LIZZI, FL ;
GREENEBAUM, M ;
FELEPPA, EJ ;
ELBAUM, M ;
COLEMAN, DJ .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1983, 73 (04) :1366-1373
[3]  
LIZZI FL, 1992, ACOUST IMAGING, P353
[4]   AGE-DETERMINATION OF EXPERIMENTAL VENOUS THROMBI BY ULTRASONIC TISSUE CHARACTERIZATION [J].
PARSONS, RE ;
SIGEL, B ;
FELEPPA, EJ ;
GOLUB, RM ;
KODAMA, I ;
LOIACONO, LA ;
JUSTIN, J ;
SWAMI, VK ;
KIMITSUKI, H ;
RORKE, M ;
YAREMKO, MM ;
LONG, CD ;
CAN, A ;
LIZZI, FL .
JOURNAL OF VASCULAR SURGERY, 1993, 17 (03) :470-478
[5]   ANALYSIS OF BLOOD-CLOT ECHOGENICITY [J].
PETER, DJ ;
FLANAGAN, LD ;
CRANLEY, JJ .
JOURNAL OF CLINICAL ULTRASOUND, 1986, 14 (02) :111-116
[6]   ULTRASONIC TISSUE CHARACTERIZATION OF BLOOD DURING STASIS AND THROMBOSIS WITH A REAL-TIME LINEAR-ARRAY BACKSCATTER IMAGING-SYSTEM [J].
RECCHIA, D ;
WICKLINE, SA .
CORONARY ARTERY DISEASE, 1993, 4 (11) :987-994
[7]   POWER DOPPLER US - A POTENTIALLY USEFUL ALTERNATIVE TO MEAN FREQUENCY-BASED COLOR DOPPLER US [J].
RUBIN, JM ;
BUDE, RO ;
CARSON, PL ;
BREE, RL ;
ADLER, RS .
RADIOLOGY, 1994, 190 (03) :853-856
[8]  
SALLESCUNHA S, 1994, 17 ANN C SOC VASC TE
[9]  
SIGEL B, 1990, SURG CLIN N AM, V70, P13
[10]  
Wakefield T W, 1997, Cardiovasc Surg, V5, P6, DOI 10.1016/S0967-2109(96)00083-X