Gas-phase dissociation of hemoglobin

被引:45
作者
Versluis, C
Heck, AJR
机构
[1] Univ Utrecht, Dept Biomol Mass Spectrometry, Bijvoet Ctr Biomol Res, NL-3584 CA Utrecht, Netherlands
[2] Univ Utrecht, Utrecht Inst Pharmaceut Sci, NL-3584 CA Utrecht, Netherlands
关键词
hemoglobin; noncovalent complexes; CAD MS/MS; protein assemblies;
D O I
10.1016/S1387-3806(01)00428-6
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
The collisionally induced gas-phase dissociation of protein assemblies of hemoglobin has been investigated. In particular, the gas-phase disassembly of the holo-hetero-dimers and the holo-tetramers of bovine, porcine, and human hemoglobin have been studied. The holo-hetero-dimer ions dissociate primarily in apo-alpha -chains and holo-beta -chains, whereby the apo-alpha -chain ions accommodate more than a fair share of the initial charges present on the precursor ions. Comparing the collision-activated dissociation tandem mass spectrometry of three holo-tetramer assemblies one of the most important findings is that also these ions dissociate predominantly into the alpha -chain monomer concomitant with the alpha beta (2) trimer, whereby the alpha -chain monomer retains primarily 0 or 1, and the trimer 2-4 heme groups. Again the apo-a-chain ions accommodate more than a fair share of the initial charges, sometimes even more than the much larger alpha beta (2) trimer. The disparate charge distribution following the dissociation is in agreement with previous observations on other protein assemblies, and may to some extent be explained by assuming a charge-droplet fission model. Some significant differences are observed in the gas-phase disassembly of the hemoglobin complexes originating from the three different species. It is thought that these differences originate from differences in the gas-phase structures of these assemblies. The observed gas-phase dissociation patterns are in sharp contrast to the known solution-phase behaviour, providing a further indication that caution has to be taken when relating gas-phase data to solution-phase properties. (C) 2001 Elsevier Science B.V.
引用
收藏
页码:637 / 649
页数:13
相关论文
共 24 条
[1]  
Antonini E., 1971, HEMOGLOBIN MYOGLOBIN
[2]   Assessing the relative stabilities of engineered hemoglobins using electrospray mass spectrometry [J].
Apostol, I .
ANALYTICAL BIOCHEMISTRY, 1999, 272 (01) :8-18
[3]   Probing the oligomeric structure of an enzyme by electrospray ionization time-of-flight mass spectrometry [J].
Fitzgerald, MC ;
Chernushevich, I ;
Standing, KG ;
Whitman, CP ;
Kent, SBH .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (14) :6851-6856
[4]   Electrospray ionization mass spectrometric determination of the molecular mass of the ∼200-kDa globin dodecamer subassemblies in hexagonal bilayer hemoglobins [J].
Green, BN ;
Bordoli, RS ;
Hanin, LG ;
Lallier, FH ;
Toulmond, A ;
Vinogradov, SN .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1999, 274 (40) :28206-28212
[5]   Dissociation of heme from myoglobin and cytochrome b(5): Comparison of behavior in solution and the gas phase [J].
Hunter, CL ;
Mauk, AG ;
Douglas, DJ .
BIOCHEMISTRY, 1997, 36 (05) :1018-1025
[6]   OBSERVATION OF THE HEME GLOBIN COMPLEX IN NATIVE MYOGLOBIN BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY [J].
KATTA, V ;
CHAIT, BT .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1991, 113 (22) :8534-8535
[7]   CONFORMATIONAL STABILITY OF HEME-PROTEINS IN VACUO [J].
KONISHI, Y ;
FENG, R .
BIOCHEMISTRY, 1994, 33 (32) :9706-9711
[8]   STUDIES ON HEME-BINDING IN MYOGLOBIN, HEMOGLOBIN, AND CYTOCHROME-C BY ION-SPRAY MASS-SPECTROMETRY [J].
LI, YT ;
HSIEH, YL ;
HENION, JD ;
GANEM, B .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (08) :631-637
[9]   OBSERVATION OF THE NONCOVALENT QUATERNARY ASSOCIATIONS OF PROTEINS BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY [J].
LIGHTWAHL, KJ ;
SCHWARTZ, BL ;
SMITH, RD .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1994, 116 (12) :5271-5278
[10]  
Loo JA, 1997, MASS SPECTROM REV, V16, P1