Investigation of contact and bulk resistance of conducting polymers by simultaneous two- and four-point technique

被引:69
作者
Hao, QL [1 ]
Kulikov, V [1 ]
Mirsky, VA [1 ]
机构
[1] Univ Regensburg, Inst Analyt Chem Chemo & Biosensors, D-93040 Regensburg, Germany
关键词
chemoresistor; conductometric chemosensor; electropolymerization; four-point technique; gas sensor;
D O I
10.1016/S0925-4005(03)00456-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A conventional resistance measured by two-point technique includes bulk and contact components. The contact resistance can be excluded by a four-point technique. A simultaneous use of the two- and four-point techniques allows to separate the total resistance between two electrodes for the contact and bulk parts. This approach has been used to analyze electrical coupling between metal electrodes of interdigitated structures and chemically sensitive coating formed by polyaniline (PANI). The polymer layers were deposited by electropolymerization on bare gold and platinum electrodes as well as on gold electrodes precoated by a self-assembled monolayer of 4-aminothiophenol. An exposure of the PANI films formed on interdigitated structures to gaseous HCl displays proportional changes of resistance measured by the two- and four- point techniques for platinum electrodes and for the precoated gold electrode, while a strong deviation from this proportionality was observed for the gold electrodes without precoating. The results demonstrate a high contribution of the contact resistance between PANI and bare gold electrodes into the resistance measured by the two-point technique. This contribution is small and therefore not measurable for bare platinum electrodes or for gold electrodes coated by 4-aminothiophenol. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:352 / 357
页数:6
相关论文
共 25 条
  • [1] POLYANILINE THIN-FILMS FOR GAS-SENSING
    AGBOR, NE
    PETTY, MC
    MONKMAN, AP
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1995, 28 (03) : 173 - 179
  • [2] Athawale AA, 1999, J APPL POLYM SCI, V74, P1286, DOI 10.1002/(SICI)1097-4628(19991031)74:5<1286::AID-APP26>3.0.CO
  • [3] 2-I
  • [4] Costantini N, 2000, POLYM ADVAN TECHNOL, V11, P27, DOI 10.1002/(SICI)1099-1581(200001)11:1<27::AID-PAT934>3.0.CO
  • [5] 2-K
  • [6] Application of conducting polyaniline as sensor material for ammonia
    Dhawan, SK
    Kumar, D
    Ram, MK
    Chandra, S
    Trivedi, DC
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1997, 40 (2-3) : 99 - 103
  • [7] Application of conducting polymers to biosensors
    Gerard, M
    Chaubey, A
    Malhotra, BD
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (05) : 345 - 359
  • [8] Thermal stability study of conductive polyaniline/polyimide blend films on their conductivity and ESR measurement
    Han, MG
    Byun, SW
    Im, SS
    [J]. POLYMERS FOR ADVANCED TECHNOLOGIES, 2002, 13 (05) : 320 - 328
  • [9] Nanometer-scale patterning of surfaces using self-assembly chemistry .2. Preparation, characterization, and electrochemical behavior of two-component organothiol monolayers on gold surfaces
    Hayes, WA
    Kim, H
    Yue, XH
    Perry, SS
    Shannon, C
    [J]. LANGMUIR, 1997, 13 (09) : 2511 - 2518
  • [10] CHARACTERISTICS OF AN ORGANIC SEMICONDUCTOR POLYANILINE FILM AS A SENSOR FOR NH(3) GAS
    HIRATA, M
    SUN, LY
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 1994, 40 (02) : 159 - 163