Passive ventricular constraint to improve left ventricular function and mechanics in an ovine model of heart failure secondary to acute myocardial infarction

被引:27
作者
Pilla, JJ
Blom, AS
Brockman, DJ
Ferrari, VA
Yuan, D
Acker, MA
机构
[1] Univ Penn, Med Ctr, Dept Surg, Philadelphia, PA 19104 USA
[2] Univ Penn, Med Ctr, Dept Radiol, Philadelphia, PA 19104 USA
[3] Univ Penn, Med Ctr, Dept Med, Philadelphia, PA 19104 USA
关键词
D O I
10.1016/S0022-5223(03)00739-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study investigated the effects on global cardiac function and myocardial energetics of limiting progressive dilatation after infarction by means of a woven polyester jacket cardiac support device. We hypothesized that placement of the cardiac support device results in a decrease in myocardial wall stress and improvement in cardiac function and myocardial energetics. Methods: To investigate the effect of passive constraint on left ventricular function and mechanics, a total of 10 sheep were studied with pressure-volume analysis and magnetic resonance imaging. A baseline study was followed by the creation of an anterior infarct. After 1 week, the animals underwent a second study. The cardiac support device was then placed over the epicardium in 5 sheep; the remaining animals served as controls. A terminal study was performed at 2 months after the infarct. Results: The cardiac support device group at the terminal study exhibited a decrease in end-diastolic volume (control 110.3 +/- 19.8 mL vs cardiac support device 67.6 +/- 4.7 mL, P = .006) and an improved ejection fraction (control 15.5% +/- 5.7% vs cardiac support device 29.46% +/- 4.42%, P = .008) relative to the control group. Myocardial energetics were also enhanced in the cardiac support device group, as evidenced by the significant improvements in potential energy (control 2015 +/- 503 mL . mm Hg/beat vs cardiac support device 885 +/- 220 mL . mm Hg/beat, P = .006), efficiency (control 39.4% +/- 13.6% vs cardiac support device 59.8% +/- 8.5%, P = .044), and oxygen consumption (control 0.072 +/- 0.013 mL O-2/beat vs cardiac support device 0.052 +/- 0.007 mL O-2/beat, P = .034). Conclusion: Passive constraint with the cardiac support device after infarct prevents further remodeling and may stimulate reverse remodeling in heart failure secondary to acute myocardial infarction. These results suggest that in human beings placement of the cardiac support device after a large anterior myocardial infarction may be effective in halting the remodeling process that often leads to end-stage heart failure. If proved placement of a cardiac support device after large heart attacks has the potential effective, to decrease the incidence of heart failure that results after large myocardial infarctions.
引用
收藏
页码:1467 / 1476
页数:10
相关论文
共 26 条
[1]   CONTINUOUS MEASUREMENT OF LEFT-VENTRICULAR VOLUME IN ANIMALS AND HUMANS BY CONDUCTANCE CATHETER [J].
BAAN, J ;
VANDERVELDE, ET ;
DEBRUIN, HG ;
SMEENK, GJ ;
KOOPS, J ;
VANDIJK, AD ;
TEMMERMAN, D ;
SENDEN, J ;
BUIS, B .
CIRCULATION, 1984, 70 (05) :812-823
[2]   CONTINUOUS STROKE VOLUME AND CARDIAC-OUTPUT FROM INTRAVENTRICULAR DIMENSIONS OBTAINED WITH IMPEDANCE CATHETER [J].
BAAN, J ;
JONG, TTA ;
KERKHOF, PLM ;
MOENE, RJ ;
VANDIJK, AD ;
VANDERVELDE, ET ;
KOOPS, J .
CARDIOVASCULAR RESEARCH, 1981, 15 (06) :328-334
[4]   Passive epicardial containment prevents ventricular remodeling in heart failure [J].
Chaudhry, PA ;
Mishima, T ;
Sharov, VG ;
Hawkins, J ;
Alferness, C ;
Paone, G ;
Sabbah, HN .
ANNALS OF THORACIC SURGERY, 2000, 70 (04) :1275-1280
[5]   REGIONAL CARDIAC DILATATION AFTER ACUTE MYOCARDIAL-INFARCTION - RECOGNITION BY 2-DIMENSIONAL ECHOCARDIOGRAPHY [J].
EATON, LW ;
WEISS, JL ;
BULKLEY, BH ;
GARRISON, JB ;
WEISFELDT, ML .
NEW ENGLAND JOURNAL OF MEDICINE, 1979, 300 (02) :57-62
[6]   LINEARITY OF THE FRANK-STARLING RELATIONSHIP IN THE INTACT HEART - THE CONCEPT OF PRELOAD RECRUITABLE STROKE WORK [J].
GLOWER, DD ;
SPRATT, JA ;
SNOW, ND ;
KABAS, JS ;
DAVIS, JW ;
OLSEN, CO ;
TYSON, GS ;
SABISTON, DC ;
RANKIN, JS .
CIRCULATION, 1985, 71 (05) :994-1009
[7]   Infarct size and location determine development of mitral regurgitation in the sheep model [J].
Gorman, JH ;
Gorman, RC ;
Plappert, T ;
Jackson, BM ;
Hiramatsu, Y ;
St John-Sutton, MG ;
Edmunds, LH .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1998, 115 (03) :615-622
[9]   DETERMINATION OF LEFT-VENTRICULAR END-SYSTOLIC PRESSURE-VOLUME RELATIONSHIPS BY THE CONDUCTANCE (VOLUME) CATHETER TECHNIQUE [J].
KASS, DA ;
YAMAZAKI, T ;
BURKHOFF, D ;
MAUGHAN, WL ;
SAGAWA, K .
CIRCULATION, 1986, 73 (03) :586-595
[10]   Restraining infarct expansion preserves left ventricular geometry and function after acute anteroapical infarction [J].
Kelley, ST ;
Malekan, R ;
Gorman, JH ;
Jackson, BM ;
Gorman, RC ;
Suzuki, Y ;
Plappert, T ;
Bogen, DK ;
Sutton, MGS ;
Edmunds, LH .
CIRCULATION, 1999, 99 (01) :135-142