Experimental Seismic Response of a Full-Scale Six-Story Light-Frame Wood Building

被引:115
作者
van de Lindt, John W. [1 ,2 ]
Pei, Shiling [2 ,3 ]
Pryor, Steven E. [4 ]
Shimizu, H. [5 ]
Isoda, H. [6 ]
机构
[1] Univ Alabama, Dept Civil Construct & Environm Engn, Tuscaloosa, AL 35487 USA
[2] Colorado State Univ, Dept Civil & Environm Engn, Ft Collins, CO 80523 USA
[3] S Dakota State Univ, Dept Civil & Environm Engn, Brookings, SD 57006 USA
[4] Simpson Strong Tie Co, Bldg Syst, Pleasanton, CA USA
[5] Natl Res Inst Earth Sci & Disaster Prevent E Def, Miki, Kagawa, Japan
[6] Shinshu Univ, Fac Engn, Dept Architecture, Nagano 380, Japan
来源
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | 2010年 / 136卷 / 10期
基金
美国国家科学基金会;
关键词
Shake table testing; Seismic tests; Earthquake; Woodframe; Light-frame wood; Midrise building;
D O I
10.1061/(ASCE)ST.1943-541X.0000222
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In July 2009, a full-scale midrise light-frame wood apartment building was subjected to a series of earthquakes at the world's largest shake table in Mild, Japan. This article focuses on the test results of that full-scale six-story light-frame wood building. The objectives of the testing program were to (1) demonstrate that the performance-based seismic design procedure developed as part of the NEESWood project worked on the full-scale building, i.e., validate the design philosophy to the extent one test can and (2) gain a better understanding of how midrise light-frame wood buildings respond, in general, to a major earthquake while providing a landmark data set to the seismic engineering research community. The building consisted of 1,350 m(2) (14,000 ft(2)) of living space and had 23 apartment units; approximately one-half one-bedroom units and one-half two-bedroom units. The building was subjected to three earthquakes ranging from seismic intensities corresponding to the 72-year event to the 2,500-year event for Los Angeles. In this paper, the construction of the NEESWood Capstone Building is explained and the resulting seismic response in terms of base shears, selected wall drifts, global interstory drifts, accelerations, hold-down forces, and roof drifts are presented. Detailed damage inspection was performed following each test and those results are summarized also. The building performed excellently with little damage even following the 2,500-year earthquake. The global drift at roof level was approximately 0.25 m and maximum interstory drifts were approximately 2% for the floor average with individual wall drifts reaching just over 3% in one corner of the building at the fifth story.
引用
收藏
页码:1262 / 1272
页数:11
相关论文
共 7 条
[1]   Seismic testing of two-story woodframe house: Influence of wall finish materials [J].
Filiatrault, A ;
Fischer, D ;
Folz, B ;
Uang, CM .
JOURNAL OF STRUCTURAL ENGINEERING, 2002, 128 (10) :1337-1345
[2]   Experimental Seismic Response of a Full-Scale Light-Frame Wood Building [J].
Filiatrault, Andre ;
Christovasilis, Ioannis P. ;
Wanitkorkul, Assawin ;
van de Lindt, John W. .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2010, 136 (03) :246-254
[3]  
ICBO, 1988, P INT C BUILD OFF WH
[4]  
Mosalam KM, 2003, W19 CUREE
[5]  
Pang W.C, 2007, NW02 NEESWOOD TEX A
[6]   Simplified Direct Displacement Design of Six-Story Woodframe Building and Pretest Seismic Performance Assessment [J].
Pang, Weichiang ;
Rosowsky, David V. ;
Pei, Shiling ;
van de Lindt, John W. .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2010, 136 (07) :813-825
[7]  
PEI S, 2010, NW04 NEESWOOD COL ST