Central venous-arterial carbon dioxide difference as an indicator of cardiac index

被引:146
作者
Cuschieri, J
Rivers, EP
Donnino, MW
Katilius, M
Jacobsen, G
Nguyen, HB
Pamukov, N
Horst, HM
机构
[1] Henry Ford Hlth Syst, Dept Emergency Med, Detroit, MI 48202 USA
[2] Henry Ford Hlth Syst, Dept Surg, Detroit, MI USA
关键词
carbon dioxide; cardiac output; central venous; hemodynamics; venous-arterial pCO(2) difference;
D O I
10.1007/s00134-005-2602-8
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: The mixed venous-arterial ( v-a) pCO(2) difference has been shown to be inversely correlated with the cardiac index (CI). A central venous pCO(2), which is easier to obtain, may provide similar information. The purpose of this study was to examine the correlation between the central venous-arterial pCO(2) difference and CI. Design: Prospective, cohort study. Setting: Intensive care unit of an urban tertiary care hospital. Patients and participants: Eighty-three consecutive intensive care unit patients. Measurements: Simultaneous blood gases from the arterial, pulmonary artery (PA), and central venous ( CV) catheters were obtained. At the same time point, cardiac indices were measured by the thermodilution technique ( an average of three measurements). The cardiac indices obtained by the venous-arterial differences were compared with those determined by thermodilution. Results: The correlation (R-2) between the mixed venous-arterial pCO(2) difference and cardiac index was 0.903 ( p < 0.0001), and the correlation between the central venous-arterial pCO(2) difference and cardiac index was 0.892 ( p < 0.0001). The regression equations for these relationships were natural log (CI)= 1.837 - 0.159 (v-a) CO2 for the PA and natural log ( CI)= 1.787 - 0.151 (v-a) CO2 for the CV ( p < 0.0001 for both). The root-mean-squared error for the PA and CV regression equations were 0.095 and 0.101, respectively. Conclusion: Venous-arterial pCO(2) differences obtained from both the PA and CV circulations inversely correlate with the cardiac index. Substitution of a central for a mixed venous-arterial pCO(2) difference provides an accurate alternative method for calculation of cardiac output.
引用
收藏
页码:818 / 822
页数:5
相关论文
共 19 条
  • [1] VENOARTERIAL CARBON-DIOXIDE GRADIENT IN HUMAN SEPTIC SHOCK
    BAKKER, J
    VINCENT, JL
    GRIS, P
    LEON, M
    COFFERNILS, M
    KAHN, RJ
    [J]. CHEST, 1992, 101 (02) : 509 - 515
  • [2] Cavaliere F, 1996, J CARDIOVASC SURG, V37, P499
  • [3] CUSCHIERI J, 1998, CRIT CARE MED, V26, pA56
  • [4] ARTERIAL-VENOUS CARBON-DIOXIDE TENSION DIFFERENCE DURING SEVERE HEMORRHAGE AND RESUSCITATION
    DUCEY, JP
    LAMIELL, JM
    GUELLER, GE
    [J]. CRITICAL CARE MEDICINE, 1992, 20 (04) : 518 - 522
  • [5] THE RELATIONSHIP BETWEEN THE ARTERIOVENOUS CARBON-DIOXIDE GRADIENT AND CARDIAC INDEX
    DURKIN, R
    GERGITS, MA
    REED, JF
    FITZGIBBONS, J
    [J]. JOURNAL OF CRITICAL CARE, 1993, 8 (04) : 217 - 221
  • [6] HIDDEN HYPERCAPNIA IN HEMORRHAGIC HYPOTENSION
    HALMAGYI, DF
    KENNEDY, M
    VARGA, D
    [J]. ANESTHESIOLOGY, 1970, 33 (06) : 594 - +
  • [7] Estimation of mixed venous PCO2 for determination of cardiac output in children
    Jacob, SV
    Hornby, L
    Lands, LC
    [J]. CHEST, 1997, 111 (02) : 474 - 480
  • [8] REDEFINING ISCHEMIA DUE TO CIRCULATORY FAILURE AS DUAL DEFECTS OF OXYGEN DEFICITS AND OF CARBON-DIOXIDE EXCESSES
    JOHNSON, BA
    WEIL, MH
    [J]. CRITICAL CARE MEDICINE, 1991, 19 (11) : 1432 - 1438
  • [9] Combination of venoarterial PCO2 difference with arteriovenous O2 content difference to detect anaerobic metabolism in patients
    Mekontso-Dessap, A
    Castelain, V
    Anguel, N
    Bahloul, M
    Schauvliege, F
    Richard, C
    Teboul, JL
    [J]. INTENSIVE CARE MEDICINE, 2002, 28 (03) : 272 - 277
  • [10] PITTMAN J, 2003, YB INTENSIVE CARE EM, P481