An experimental study of MR dampers for seismic protection

被引:463
作者
Dyke, SJ
Spencer, BF
Sain, MK
Carlson, JD
机构
[1] Washington Univ, Dept Civil Engn, St Louis, MO 63130 USA
[2] Univ Notre Dame, Dept Civil Engn & Geol Sci, Notre Dame, IN 46556 USA
[3] Univ Notre Dame, Dept Elect Engn, Notre Dame, IN 46556 USA
[4] Lord Corp, Mech Prod Div, Cary, NC 27511 USA
关键词
D O I
10.1088/0964-1726/7/5/012
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, the efficacy of magnetorheological (MR) dampers for seismic response reduction is examined. To investigate the performance of the MR damper, a series of experiments was conducted in which the MR damper is used in conjunction with a recently developed clipped-optimal control strategy to control a three-story test structure subjected to a one-dimensional ground excitation. The ability of the MR damper to reduce both peak responses, in a series of earthquake tests, and rms responses, in a series of broadband excitation tests, is shown. Additionally, because semi-active control systems are nonlinear, a variety of disturbance amplitudes are considered to investigate the performance of this control system over a variety of loading conditions. For each case, the results for three clipped-optimal control designs are presented and compared to the performance of two passive systems. The results indicate that the MR damper is quite effective for structural response reduction over a wide class of seismic excitations.
引用
收藏
页码:693 / 703
页数:11
相关论文
共 38 条
[1]  
[Anonymous], P 3 INT C MOT VIBR C
[2]  
CARLSON JD, 1995, Patent No. 5382373
[3]  
CARLSON JD, 1994, P ACT 94, P266
[4]  
CARLSON JD, 1994, MACH DES, P61
[5]  
Carlton James T., 1996, P99
[6]   EXPERIMENTAL-STUDY OF ACTIVE CONTROL FOR MDOF SEISMIC STRUCTURES [J].
CHUNG, LL ;
LIN, RC ;
SOONG, TT ;
REINHORN, AM .
JOURNAL OF ENGINEERING MECHANICS-ASCE, 1989, 115 (08) :1609-1627
[7]  
Dyke S.J., 1996, Acceleration feedback control strategies for active and semi-active systems: modeling, alogrithm development and experimental verification
[8]  
Dyke S.J., 1996, P 3 INT C MOT VIBR C, V3, P291
[9]   ROLE OF CONTROL-STRUCTURE INTERACTION IN PROTECTIVE SYSTEM-DESIGN [J].
DYKE, SJ ;
SPENCER, BF ;
QUAST, P ;
SAIN, MK .
JOURNAL OF ENGINEERING MECHANICS-ASCE, 1995, 121 (02) :322-338
[10]   Acceleration feedback control of MDOF structures [J].
Dyke, SJ ;
Spencer, BF ;
Quast, P ;
Sain, MK ;
Kaspari, DC ;
Soong, TT .
JOURNAL OF ENGINEERING MECHANICS-ASCE, 1996, 122 (09) :907-918