Potential added value of three-dimensional reconstruction and display of single photon emission computed tomographic gated blood pool images

被引:17
作者
Botvinick, EH
O'Connell, JW
Kadkade, PP
Glickman, SL
Dae, MW
Cohen, TJ
Abbott, J
Krishnan, R
机构
[1] Univ Calif San Francisco, Med Ctr, Dept Radiol, Nucl Med Sect, San Francisco, CA 94143 USA
[2] Univ Calif San Francisco, Dept Med, Div Cardiovasc, San Francisco, CA 94143 USA
[3] Univ Calif San Francisco, Inst Cardiovasc Res, San Francisco, CA 94143 USA
关键词
3-D volume-rendered images; visual separation; planar first-harmonic phase analysis;
D O I
10.1016/S1071-3581(98)90126-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Single photon emission computed tomographic (SPECT) acquisition provides potential advantages for blood pool imaging. However, the method has been little applied. Methods. An improved method of three-dimensional (3-D) reconstruction and display of SPECT equilibrium blood pool scintigrams and related phase data was developed, Dynamic slices and volume-rendered dynamic 3-D images were displayed. Images were viewed from each of 34 solid angles referenced to a sphere surrounding the reconstruction field. Each image pixel was "painted" with intensity-coded regional amplitude and color-coded for its phase angle, The method was applied to evaluate the cardiac anatomy, regional contraction, and related conduction sequence at rest in 17 patients, Twelve had normal left ventricular function including 7 patients with minimal septal preexcitation. Five patients had abnormal left ventricular function, including 2 with left bundle branch block. Results. Slices contained all of the functional information, but necessary data integration was time-consuming and evaluation of chamber size and anatomy was difficult. Three-dimensional projection images condensed and integrated the data, presenting new vantage points on anatomy, contraction, and conduction not otherwise available in the clinically limited angulations of planar images, This provided excellent visual separation of cardiac chambers with full and increased visualization of right and left ventricular wall motion in all segments compared with the conventional projections acquired clinically (p < 0.05). Atria and great vessels were well separated with evident size and function. Phase-angle progression paralleled the electrocardiogram, permitting bypass pathway localization and the direct noninvasive localization of posteroseptal pathways. Conclusions. The 3-D method permits greater access to and utilization of SPECT blood pool image data. It suggests specific advantages for clinical use.
引用
收藏
页码:245 / 255
页数:11
相关论文
共 32 条
[1]   AUGMENTED PREEXCITATION ASSESSED BY SCINTIGRAPHIC PHASE-ANALYSIS DURING ATRIAL-PACING [J].
BOTVINICK, E ;
SCHECHTMANN, N ;
DAE, M ;
SCHEINMAN, M ;
DAVIS, J ;
HERRE, J ;
ISKIKIAN, T ;
ABBOTT, J .
AMERICAN HEART JOURNAL, 1987, 114 (04) :738-745
[2]  
Botvinick E H, 1989, Cardiol Clin, V7, P537
[3]  
BOTVINICK EH, 1994, J AM COLL CARDIOL, V3, P799
[4]  
CALLAHAN RJ, 1982, J NUCL MED, V23, P315
[5]   TOMOGRAPHIC RADIONUCLIDE VENTRICULOGRAPHY - OPPORTUNITY IGNORED [J].
CORBETT, JR .
JOURNAL OF NUCLEAR CARDIOLOGY, 1994, 1 (06) :567-570
[6]   TOMOGRAPHIC GATED BLOOD POOL RADIONUCLIDE VENTRICULOGRAPHY - ANALYSIS OF WALL MOTION AND LEFT-VENTRICULAR VOLUMES IN PATIENTS WITH CORONARY-ARTERY DISEASE [J].
CORBETT, JR ;
JANSEN, DE ;
LEWIS, SE ;
GABLIANI, GI ;
NICOD, P ;
FILIPCHUK, NG ;
REDISH, GA ;
AKERS, MS ;
WOLFE, CL ;
RELLAS, JS ;
PARKEY, RW ;
WILLERSON, JT .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (02) :349-358
[7]  
CORBETT JR, 1990, J NUCL MED, V31, pA838
[8]  
DAE M, 1987, American Journal of Noninvasive Cardiology, V1, P155
[9]   A MODEL-BASED 4-DIMENSIONAL LEFT-VENTRICULAR SURFACE DETECTOR [J].
FABER, TL ;
STOKELY, EM ;
PESHOCK, RM ;
CORBETT, JR .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :321-329
[10]  
FABER TL, 1989, J NUCL MED, V30, P639