Improved acidosis correction and recovery of mesothelial cell mass with neutral-pH bicarbonate dialysis solution among children undergoing automated peritoneal dialysis

被引:80
作者
Haas, S
Schmitt, CP
Arbeiter, K
Bonzel, KE
Fischbach, M
John, U
Pieper, AK
Schaub, TP
Passlick-Deetjen, J
Mehls, O
Schaefer, F
机构
[1] Heidelberg Univ, Childrens Hosp, Div Pediat Nephrol, D-69120 Heidelberg, Germany
[2] Univ Vienna, Childrens Hosp, Vienna, Austria
[3] Univ Essen Gesamthsch, Childrens Hosp, Essen, Germany
[4] Univ Strasbourg, Hautepierre Hosp, Strasbourg, France
[5] Univ Jena, Childrens Hosp, D-6900 Jena, Germany
[6] Humboldt Univ, Charite Childrens Hosp, Berlin, Germany
[7] Fresenius Med Care, Homburg, Germany
来源
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY | 2003年 / 14卷 / 10期
关键词
D O I
10.1097/01.ASN.0000086475.83211.DF
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Acid-base balance and peritoneal membrane longevity are of utmost relevance for pediatric patients undergoing peritoneal dialysis (PD). PD fluids with neutral pH and reduced glucose degradation product contents are considered more bio-compatible, because they preserve peritoneal cell functions in vitro. To investigate the clinical effects of a novel PD fluid buffered with 34 mM pure bicarbonate at neutral pH, a randomized, prospective, crossover comparison with conventional, acidic, 35 mM lactate PD fluid was performed for two consecutive 12-wk periods with 28 children (age, 6 mo to 15 yr) undergoing automated PD (APD). Blood bicarbonate levels and arterial pH were significantly higher after 3 mo of bicarbonate PD (24.6 +/- 2.3 mM and 7.43 +/- 0.06, respectively), compared with lactate PD (22.8 +/- 3.9 mM and 7.38 +/- 0.05, respectively; P < 0.05). This effect was reversible among patients who returned from bicarbonate to lactate fluid. Low initial pH and young patient age independently predicted in-creased blood pH during bicarbonate APD. Peritoneal equilibration tests revealed subtle changes in solute transport, with a less steep creatinine equilibration curve during bicarbonate dialysis, suggesting reduced peritoneal vasodilation. The peritoneal release of carcinogen antigen-125 increased twofold during bicarbonate APD (29 +/- 15 versus 15 +/- 8 U/ml per 4 h, P < 0.01), which is consistent with recovery of the mesothelial cell layer. This effect was fully reversed when the patients returned to lactate fluid. Effluent carcinogen antigen-125 levels were inversely correlated with peritoneal glucose exposure during lactate but not bicarbonate APD, indicating improved in vivo mesothelial cell tolerance of high-dose glucose with the neutral-pH PD fluid with reduced glucose degradation product content. Among children undergoing APD, neutral-pH, bicarbonate-buffered PD fluid provides more effective correction of metabolic acidosis and better preservation of peritoneal cell mass than do conventional, acidic, lactate-based fluids.
引用
收藏
页码:2632 / 2638
页数:7
相关论文
共 34 条
[1]  
[Anonymous], 1997, Am J Kidney Dis, V30, pS67
[2]  
Bouts A H, 2000, Adv Perit Dial, V16, P328
[3]   What really happens to people on long-term peritoneal dialysis? [J].
Davies, SJ ;
Phillips, L ;
Griffiths, AM ;
Russell, LH ;
Naish, PF ;
Russell, GI .
KIDNEY INTERNATIONAL, 1998, 54 (06) :2207-2217
[4]  
Davies SJ, 2001, J AM SOC NEPHROL, V12, P1046, DOI 10.1681/ASN.V1251046
[5]   Randomized long-term evaluation of bicarbonate-buffered CAPD solution [J].
Feriani, M ;
Kirchgessner, J ;
La Greca, G ;
Passlick-Deetjen, J .
KIDNEY INTERNATIONAL, 1998, 54 (05) :1731-1738
[6]  
FISCHBACH M, 2003, PERITON DIALYSIS INT, V23, pS58
[7]  
Ha H, 2002, PERITON DIALYSIS INT, V22, P171
[8]   Glucose degradation product methylglyoxal enhances the production of vascular endothelial growth factor in peritoneal cells: role in the functional and morphological alterations of peritoneal membranes in peritoneal dialysis [J].
Inagi, R ;
Miyata, T ;
Yamamoto, T ;
Suzuki, D ;
Urakami, K ;
Saito, A ;
de Strihou, CV ;
Kurokawa, K .
FEBS LETTERS, 1999, 463 (03) :260-264
[9]   Bicarbonate/lactate-based peritoneal dialysis solution increases cancer antigen 125 and decreases hyaluronic acid levels [J].
Jones, S ;
Holmes, CJ ;
Krediet, RT ;
Mackenzie, R ;
Faict, D ;
Tranaeus, A ;
Williams, JD ;
Coles, GA ;
Topley, N .
KIDNEY INTERNATIONAL, 2001, 59 (04) :1529-1538
[10]  
Kang DH, 1999, PERITON DIALYSIS INT, V19, P221