Reliability of the Spin-T cervical goniometer in measuring cervical range of motion in an asymptomatic Indian population

被引:20
作者
Agarwal, S
Allison, GT
Singer, KP
机构
[1] Belle Vue Clin, Kolkata 700017, India
[2] Ctr Musculoskeletal Studies, Perth, WA, Australia
关键词
reproducibility of results; cervical vertebrae; range of motion; articular;
D O I
10.1016/j.jmpt.2005.07.005
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Objective: To examine the intratester reliability of the Spin-T goniometer, a cervical range of motion device, in a normal Indian population. Methods: Subjects comprised 30 healthy adults with mean age of 34 years (range, 18-65 years). The subjects were stabilized in the sitting position and the Spin-T goniometer mounted on the head of the subject. The study design was a within-subject repeated intratester reliability trial conducted for cervical range of motion in 6 directions of movement. Three measurements were taken in each direction (flexion, extension lateral flexion, and lateral rotation) per participant. Reliability coefficients, intraclass correlation coefficients, and 95% confidence interval were derived from repeated-measures analysis of variance (ANOVA). Where differences in ANOVA were detected, a paired t test was conducted and the typical error values and coefficient of variance were calculated. Results: All repeated measures showed high intraclass correlation coefficients (all >0.96, P <.01). The ANOVA detected no differences between trials for all movements except rotation. The typical error values for the rotation trials did not exceed 2.5 degrees and the coefficient of variance did not exceed 4%, which is clinically acceptable considering the normally variable cervical range of movement. Conclusion: In this study, the Spin-T goniometer proved to be a reliable measuring instrument for cervical range of movement in an Indian population. The use of a laser pointer fixed to the instrument ensured a consistent neutral start position
引用
收藏
页码:487 / 492
页数:6
相关论文
共 25 条
[1]
AGARWAL S, 2005, IN PRESS J MANIPULAT, V28
[2]
Bulgheroni MV, 1998, FUNCT NEUROL, V13, P239
[3]
CASSIDY JD, 1992, J MANIP PHYSIOL THER, V15, P495
[4]
Christensen HW, 1998, J MANIP PHYSIOL THER, V21, P383
[5]
Christensen HW, 1998, J MANIP PHYSIOL THER, V21, P341
[6]
Reproducibility and instrument validity of a new ultrasonography-based system for measuring cervical spine kinematics [J].
Dvir, Z ;
Prushansky, T .
CLINICAL BIOMECHANICS, 2000, 15 (09) :658-664
[7]
RELIABILITY OF MEASURING FORWARD HEAD POSTURE IN A CLINICAL SETTING [J].
GARRETT, TR ;
YOUDAS, JW ;
MADSON, TJ .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1993, 17 (03) :155-160
[8]
Accuracy and reliability of anew, protractor-based neck goniometer [J].
Haynes, MJ ;
Edmondston, S .
JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2002, 25 (09) :579-586
[9]
Hole D E, 1995, Man Ther, V1, P36, DOI 10.1054/math.1995.0248
[10]
THE RANGE AND NATURE OF FLEXION EXTENSION MOTION IN THE CERVICAL-SPINE [J].
HOLMES, A ;
WANG, C ;
HAN, ZH ;
DANG, GT .
SPINE, 1994, 19 (22) :2505-2510