Design and evaluation of a coupled monolithic preconcentrator-capillary zone electrophoresis system for the extraction of immunoglobulin G from human serum

被引:54
作者
Armenta, JM [1 ]
Gu, BH [1 ]
Humble, PH [1 ]
Thulin, CD [1 ]
Lee, ML [1 ]
机构
[1] Brigham Young Univ, Dept Chem & Biochem, Provo, UT 84602 USA
关键词
proteins; preconcentration; monolith; protein g; capillary electrophoresis; IgG; glycidyl methacrylate; human serum;
D O I
10.1016/j.chroma.2005.08.050
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The analysis of proteins in biological fluids by capillary electrophoresis (CE) is of interest in clinical chemistry. However, due to low analyte concentrations and poor concentration limits of detection (CLOD), protein analysis by this technique is frequently challenging. Coupling preconcentration techniques with CE greatly improves the CLOD. An on-line preconcentration-CE method that can selectively preconcentrate any protein for which an antibody is available would be very useful for the analysis of low abundance proteins and would establish CE as a major tool in biomarker discovery. To accomplish this, the development of an on-line protein G monolithic preconcentrator-CE device is proposed. To generate active groups for protein immobilization, glycidyl methacrylate (GMA) was used to prepare polymer monoliths. A 1.5-2 cm monolith was cast inside a 75 mu m I.D. fused silica capillary that had previously been coated with alternating layers of negatively (dextran) and positively (polybrene) charged polymers. Protein G was covalently bound to GMA. Monoliths from different formulations were prepared and evaluated for binding capacity to optimize the monolith formulation for protein preconcentration. The physical properties of the column considered best for preconcentration were determined by mercury intrusion porosimetry. The total pore area was 4.8 m(2)/g, the average pore diameter was 3.3 mu m and the porosity was 82%. The monolith had a low flow resistance and was macroscopically homogeneous. The effectiveness of the monolith to rapidly preconcentrate proteins at flow rates as high as 10 mu L/min was demonstrated using a 1.8 mu M IgG solution. This system proved effective for on-line sample extraction, clean-up, preconcentration, and CE of IgG in human serum. IgG from diluted (500 and 65,000 times) human serum samples was successfully analyzed using this system. The approach can be applied to the on-line preconcentration and analysis of any protein for which an antibody is available. (c) 2005 Published by Elsevier B.V.
引用
收藏
页码:171 / 178
页数:8
相关论文
共 41 条