Reliability of Prehospital Real-Time Cellular Video Phone in Assessing the Simplified National Institutes of Health Stroke Scale in Patients With Acute Stroke A Novel Telemedicine Technology

被引:39
作者
Gonzalez, Manuel A. [1 ]
Hanna, Nicholas [1 ]
Rodrigo, Maria E. [1 ]
Satler, Lowell F. [1 ]
Waksman, Ron [1 ]
机构
[1] Washington Hosp Ctr, Div Cardiol, Washington, DC 20010 USA
关键词
acute stroke; cellular video phone; National Institutes of Health Stroke Scale; telemedicine; ACUTE CEREBRAL INFARCTION; ACUTE ISCHEMIC-STROKE; CLINICAL-TRIALS; INTERRATER RELIABILITY; CARE; CERTIFICATION; NEUROLOGISTS; STATEMENT; PROJECT; SYSTEMS;
D O I
10.1161/STROKEAHA.110.600296
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-The National Institutes of Health Stroke Scale (NIHSS) is the gold standard to assess patients with acute stroke. We aimed to examine the feasibility and reliability of prehospital real-time cellular video phone (VP) in performing the NIHSS. Methods-Forty physicians prospectively performed a simplified NIHSS (sNIHSS) on a standardized patient remotely using VP with the assistance of a bedside emergency medical technician and later performed a bedside examination. We tested the hypothesis that there is high reliability between these 2 methods. Physicians were timed and sNIHSS scores were recorded. Finally, physicians were asked to rate the VP technology. Results-A total of 480 pair comparisons of the sNIHSS scores between the VP and bedside examination were generated. After adjusting for the physician's specialty, level of training, and certification status, there was a strong positive linear correlation (r=0.97, P<0.01) between the 2 methods with high average physician reliability (0.99; 95% CI, 0.992 to 0.995). The mean sNIHSS scores using VP and bedside examination were not different (6.82 +/- 1.06 versus 6.63 +/- 0.98; P=0.08). The mean time to perform the sNIHSS using VP was approximately 38 seconds longer than the bedside examination (3.38 +/- 0.77 versus 2.93 +/- 0.83 minutes; P=0.006). Conclusions-The VP is a feasible, reliable, and timely tool with the potential for remotely assessing the sNIHSS for patients presenting with acute stroke and may expedite the initial evaluation and treatment strategies. (Stroke. 2011;42:1522-1527.)
引用
收藏
页码:1522 / 1527
页数:6
相关论文
共 43 条
[1]   Baseline NIH Stroke Scale score strongly predicts outcome after stroke - A report of the Trial of Org 10172 in Acute Stroke Treatment (TOAST) [J].
Adams, HP ;
Davis, PH ;
Leira, EC ;
Chang, KC ;
Bendixen, BH ;
Clarke, WR ;
Woolson, RF ;
Hansen, MD .
NEUROLOGY, 1999, 53 (01) :126-131
[2]   ENSURING RELIABILITY OF OUTCOME MEASURES IN MULTICENTER CLINICAL-TRIALS OF TREATMENTS FOR ACUTE ISCHEMIC STROKE - THE PROGRAM DEVELOPED FOR THE TRIAL OF ORG-10172 IN ACUTE STROKE TREATMENT (TOAST) [J].
ALBANESE, MA ;
CLARKE, WR ;
ADAMS, HP ;
WOOLSON, RF ;
BENDIXEN, BH ;
DAVIS, PH ;
JACOBY, MR ;
GOMEZ, FJ ;
DYKEN, ME ;
UC, EY ;
WOJCIESZEK, JM ;
KAPPELLE, LJ ;
TANNA, AB ;
MITCHELL, VL ;
GOMEZ, CR ;
MALKOFF, MD ;
TULYAPRONCHOTE, R ;
SAUER, CM ;
RIAZ, G ;
SCHMIDT, JG ;
MALIK, MM ;
BANET, GA ;
KARANJIA, PN ;
MADDEN, KP ;
RUGGLES, KH ;
MICKEL, SF ;
GOTTSCHALK, PG ;
HANSOTIA, PL ;
SORENSON, RW ;
JACOBSON, DM ;
HINER, BC ;
MANCL, K ;
LUKASIK, E ;
BRUNO, A ;
LAKIND, ED ;
JEFFREY, DR ;
MLADINICH, EK ;
IQBAL, J ;
REINERS, M ;
BARRETT, DW ;
SHIBUYA, D ;
WILLIAMS, JK ;
RUSSELL, P ;
KING, MK ;
CHAPIN, JE ;
CARTER, S ;
JEFFRIES, L ;
HIER, DB ;
SHAPIRO, RA ;
BRINT, SU .
STROKE, 1994, 25 (09) :1746-1751
[3]  
Audebert HJ, 2009, NERVENARZT, V80, P184, DOI 10.1007/s00115-008-2657-1
[4]   Long-Term Effects of Specialized Stroke Care With Telemedicine Support in Community Hospitals on Behalf of the Telemedical Project for Integrative Stroke Care (TEMPiS) [J].
Audebert, Heinrich J. ;
Schultes, Kathrin ;
Tietz, Viola ;
Heuschmann, Peter U. ;
Bogdahn, Ulrich ;
Haberl, Roman L. ;
Schenkel, Johannes .
STROKE, 2009, 40 (03) :902-908
[5]   MEASUREMENTS OF ACUTE CEREBRAL INFARCTION - A CLINICAL EXAMINATION SCALE [J].
BROTT, T ;
ADAMS, HP ;
OLINGER, CP ;
MARLER, JR ;
BARSAN, WG ;
BILLER, J ;
SPILKER, J ;
HOLLERAN, R ;
EBERLE, R ;
HERTZBERG, V ;
RORICK, M ;
MOOMAW, CJ ;
WALKER, M .
STROKE, 1989, 20 (07) :864-870
[6]   MEASUREMENTS OF ACUTE CEREBRAL INFARCTION - LESION SIZE BY COMPUTED-TOMOGRAPHY [J].
BROTT, T ;
MARLER, JR ;
OLINGER, CP ;
ADAMS, HP ;
TOMSICK, T ;
BARSAN, WG ;
BILLER, J ;
EBERLE, R ;
HERTZBERG, V ;
WALKER, M .
STROKE, 1989, 20 (07) :871-875
[7]   Using Telemedicine to Facilitate Thrombolytic Therapy for Patients with Acute Stroke [J].
Choi, John Y. ;
Porche, Nichole A. ;
Albright, Karen C. ;
Khaja, Aslam M. ;
Ho, Victor S. ;
Grotta, James C. .
JOINT COMMISSION JOURNAL ON QUALITY AND PATIENT SAFETY, 2006, 32 (04) :199-205
[8]   Barriers, Legal Issues, Limitations and Ongoing Questions in Telemedicine Applied to Stroke [J].
de Bustos, Elisabeth Medeiros ;
Moulin, Thierry ;
Audebert, Heinrich J. .
CEREBROVASCULAR DISEASES, 2009, 27 (SUPPL 4) :36-39
[9]   Vascular Neurology Nurse Practitioner Provision of Telemedicine Consultations [J].
Demaerschalk, Bart M. ;
Kiernan, Terri-Ellen J. .
INTERNATIONAL JOURNAL OF TELEMEDICINE AND APPLICATIONS, 2010, 2010
[10]   Stroke Telemedicine [J].
Demaerschalk, Bart M. ;
Miley, Madeline L. ;
Kiernan, Terri-Ellen J. ;
Bobrow, Bentley J. ;
Corday, Doren A. ;
Wellik, Kay E. ;
Aguilar, Maria I. ;
Ingall, Timothy J. ;
Dodick, David W. ;
Brazdys, Karina ;
Koch, Tiffany C. ;
Ward, Michael P. ;
Richemont, Phillip C. .
MAYO CLINIC PROCEEDINGS, 2009, 84 (01) :53-64