Analytical methods for the determination of acrylamide in food products: a review

被引:155
作者
Wenzl, T [1 ]
de la Calle, MB [1 ]
Anklam, E [1 ]
机构
[1] Commiss European Communities, Joint Res Ctr, Directorate Gen,Food Safety & Qual Unit, Inst Reference Mat & Measurements, B-2440 Geel, Belgium
来源
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT | 2003年 / 20卷 / 10期
关键词
review; acrylamide; analytical methods; GC/MS; LC/MS/MS; proficiency testing;
D O I
10.1080/02652030310001605051
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
In early 2002, the Swedish National Food Administration reported high acrylamide levels in heat-treated carbohydrate-rich foods. Consequently, intensive activity began examining the many different types of food, and thousands of analyses have been undertaken world wide. Measurement data have been published in many different types of media. Within this flood of publications, there are only a limited number of articles concerned with the technical aspects of the measurements. This review focuses on the state-of-the-art in the analysis of acrylamide in foodstuffs. It covers information on methods from peer-reviewed articles and other sources (e.g. a survey carried out among official and private laboratories of the Member States of the European Union). Alternative methods are presented and discussed alongside the more common measurement techniques for acrylamide in foodstuffs. Special attention is given to sample preparation. The greatest differences between the analytical methods was for acrylamide extraction and clean-up. The influence of different extraction techniques or extraction solvents/solvent mixtures on the measurement results has not yet been fully investigated. There is also a lack of understanding about the sample clean-up. Since both might have a large impact on the results of the analysis, this review should also be considered as a basis for further investigations.
引用
收藏
页码:885 / 902
页数:18
相关论文
共 37 条
[1]   Verification of the findings of acrylamide in heated foods [J].
Ahn, JS ;
Castle, L ;
Clarke, DB ;
Lloyd, AS ;
Philo, MR ;
Speck, DR .
FOOD ADDITIVES AND CONTAMINANTS, 2002, 19 (12) :1116-1124
[2]  
ANDRAWES F, 1987, J CHROMATOGR, V399, P269
[3]  
[Anonymous], 2002, INF ACR FOOD
[4]   Acrylamide in foods: Occurrence, sources, and modeling [J].
Becalski, A ;
Lau, BPY ;
Lewis, D ;
Seaman, SW .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (03) :802-808
[5]  
Biedermann Maurus, 2002, Mitteilungen aus Lebensmitteluntersuchung und Hygiene, V93, P638
[6]   DETERMINATION OF ACRYLAMIDE MONOMER IN HYDROPONICALLY GROWN TOMATO FRUITS BY CAPILLARY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
CASTLE, L ;
CAMPOS, MJ ;
GILBERT, J .
JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 1991, 54 (04) :549-555
[7]   DETERMINATION OF ACRYLAMIDE MONOMER IN MUSHROOMS GROWN ON POLYACRYLAMIDE-GEL [J].
CASTLE, L .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1993, 41 (08) :1261-1263
[8]  
Castle L., 2003, WORKSH AN METH ACR D
[9]  
CAVALLI S, 2002, FAST DETERMINATION A, P1
[10]  
Clarke DB, 2002, J AOAC INT, V85, P1370