Computation of electric and magnetic stimulation in human head using the 3D impedance method

被引:105
作者
Nadeem, M
Thorlin, T
Gandhi, OP
Persson, M
机构
[1] Chalmers, Dept Electromagnet, S-41296 Gothenburg, Sweden
[2] Gothenburg Univ, Inst Clin Neurosci, S-41345 Gothenburg, Sweden
[3] Univ Utah, Dept Elect Engn, Salt Lake City, UT 84112 USA
关键词
D O I
10.1109/TBME.2003.813548
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A comparative, computational study of the modeling of transcranial magnetic stimulation (TMS) and electroconvulsive therapy (ECT) is presented using a human head model. The magnetic fields from a typical TMS coil of figure-eight type is modeled using the Biot-Savart law. The TMS coil is placed in a position used clinically for treatment of depression. Induced current densities and electric field distributions are calculated in the model using the impedance method. The calculations are made using driving currents and wave forms typical in the clinical setting. The obtained results are compared and contrasted with the corresponding ECT results. In the ECT case, a uniform current density is injected on one side of the head and extracted from the equal area on the opposite side of the head. The area of the injected currents corresponds to the electrode placement used in the clinic. The currents and electric fields, thus, produced within the model are computed using the same three-dimensional impedance method as used for the TMS case. The ECT calculations are, made using. currents and wave forms typical in the clinic. The electrical tissue properties are obtained from a 4-Cole-Cole model. The numerical results obtained are shown on a two-dimenainnal cross section of the model. In this study, we find that the current densities and electric fields in the ECT case are stronger and deeper penetrating than the corresponding TMS quantities but both methods show biologically interesting current levels deep inside the brain.
引用
收藏
页码:900 / 907
页数:8
相关论文
共 20 条
[1]  
[Anonymous], 1997, Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies
[2]  
BOLIN K, 2001, PFIZER HLTH EC WORKI, P56
[3]   MAMMALIAN CORTICAL ASTROCYTES ALIGN THEMSELVES IN A PHYSIOLOGICAL VOLTAGE GRADIENT [J].
BORGENS, RB ;
SHI, RY ;
MOHR, TJ ;
JAEGER, CB .
EXPERIMENTAL NEUROLOGY, 1994, 128 (01) :41-49
[4]   Dispersion and absorption in dielectrics I. Alternating current characteristics [J].
Cole, KS ;
Cole, RH .
JOURNAL OF CHEMICAL PHYSICS, 1941, 9 (04) :341-351
[5]   Neurogenesis in the adult human hippocampus [J].
Eriksson, PS ;
Perfilieva, E ;
Björk-Eriksson, T ;
Alborn, AM ;
Nordborg, C ;
Peterson, DA ;
Gage, FH .
NATURE MEDICINE, 1998, 4 (11) :1313-1317
[6]  
FERRE TC, 1999, INT J BIOELECTROMAGN, V1, P1
[7]   The dielectric properties of biological tissues .1. Literature survey [J].
Gabriel, C ;
Gabriel, S ;
Corthout, E .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2231-2249
[8]   The dielectric properties of biological tissues .2. Measurements in the frequency range 10 Hz to 20 GHz [J].
Gabriel, S ;
Lau, RW ;
Gabriel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2251-2269
[9]   SOME NUMERICAL-METHODS FOR DOSIMETRY - EXTREMELY LOW-FREQUENCIES TO MICROWAVE-FREQUENCIES [J].
GANDHI, OP .
RADIO SCIENCE, 1995, 30 (01) :161-177
[10]   CALCULATION OF EM POWER DEPOSITION FOR OPERATOR EXPOSURE TO RF INDUCTION HEATERS [J].
GANDHI, OP ;
DEFORD, JF .
IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 1988, 30 (01) :63-68