Effect of selective aortic arch perfusion on median frequency and peak amplitude of ventricular fibrillation in a canine model

被引:17
作者
Barton, C [1 ]
Manning, JE [1 ]
Batson, N [1 ]
机构
[1] UNIV N CAROLINA,DEPT EMERGENCY MED,CHAPEL HILL,NC 27599
关键词
D O I
10.1016/S0196-0644(96)70165-8
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: To determine whether the computer-derived measures of median frequency or peak amplitude of ventricular fibrillation (VF), obtained by fast Fourier transform of the VF waveform, change during selective aortic arch perfusion in a canine model of cardiac arrest. Methods: Eight mongrel dogs (including 4 control animals) were sedated, intubated, catheterized, and instrumented to record the electrocardiogram (digitally at 100 Hz, filtered with a finite impulse response filter at 2 Hz), right atrial pressure, and aortic pressure during resuscitation in a model of VF-induced cardiac arrest. After 10 minutes of VF-induced arrest, cardiopulmonary resuscitation (CPR) with a mechanical chest compression device was initiated. Beginning 2 minutes later, the 4 study animals received, every 2 minutes, 45 seconds of selective aortic arch perfusion (SAAP) with autologous blood infusions under high pressure. Defibrillation was attempted after 3 minutes of CPR and every minute thereafter. Both study and control groups received standard-dose epinephrine (.01 mg/kg) every 3 minutes by means of an intraaortic catheter. The median frequency, peak amplitude, and coronary perfusion pressure (CPP) during the 5-second period just before defibrillation were obtained with the use of computer algorithms. Results: All SAAP animals and 1 control animal were resuscitated. Baseline measures of median frequency (8.4+/-1.5 versus 6.6+/-1.0 Hz) and peak amplitude (.18+/-.05 versus .36+/-.13 mV) were not different between the SAAP and control groups, respectively, at the start of CPR. SAAP infusion resulted insignificant increases in the SAAP group compared with the control group: median frequency, 9.6+/-.4 versus 7.3+/-1.4 Hz; peak amplitude, .74+/-.21 versus .39+/-.15 mV; and CPP, 40.5+/-7.1 versus 18.0+/-15.0 mm Hg, respectively. Median frequency correlated with CPP (r(2)=.67). Peak amplitude did not correlate with CPP (r(2)=.06).
引用
收藏
页码:610 / 616
页数:7
相关论文
共 17 条
[1]  
BRAUNWALD E, 1976, CIRCULATION, V53, P1
[2]  
BROWN C, 1988, ANN EMERG MED, V17, P436
[3]   MYOCARDIAL OXYGEN DELIVERY CONSUMPTION DURING CARDIOPULMONARY RESUSCITATION - A COMPARISON OF EPINEPHRINE AND PHENYLEPHRINE [J].
BROWN, CG ;
TAYLOR, RB ;
WERMAN, HA ;
LUU, T ;
ASHTON, J ;
HAMLIN, RL .
ANNALS OF EMERGENCY MEDICINE, 1988, 17 (04) :302-308
[4]   ESTIMATING THE DURATION OF VENTRICULAR-FIBRILLATION [J].
BROWN, CG ;
DZWONCZYK, R ;
WERMAN, HA ;
HAMLIN, RL .
ANNALS OF EMERGENCY MEDICINE, 1989, 18 (11) :1181-1185
[5]   PREHOSPITAL CARDIAC-ARREST TREATED BY URBAN 1ST-RESPONDERS - PROFILE OF PATIENT RESPONSE AND PREDICTION OF OUTCOME BY VENTRICULAR-FIBRILLATION WAVE-FORM [J].
CALLAHAM, M ;
BRAUN, O ;
VALENTINE, W ;
CLARK, DM ;
ZEGANS, C .
ANNALS OF EMERGENCY MEDICINE, 1993, 22 (11) :1664-1677
[6]   PHARMACOLOGICAL ANALYSIS OF ESTABLISHED VENTRICULAR-FIBRILLATION [J].
CARLISLE, EJF ;
ALLEN, JD ;
KERNOHAN, WG ;
LEAHEY, W ;
ADGEY, AAJ .
BRITISH JOURNAL OF PHARMACOLOGY, 1990, 100 (03) :530-534
[7]   OXYGEN CONSUMPTION AND CORONARY VASCULAR TONE IN THE ISOLATED FIBRILLATING DOG HEART [J].
HASHIMOTO, K ;
SHIGEI, T ;
IMAI, S ;
SAITO, Y ;
YAGO, N ;
UEI, I ;
CLARK, RE .
AMERICAN JOURNAL OF PHYSIOLOGY, 1960, 198 (05) :965-970
[8]  
Herbschleb J. N., 1980, Computers in Cardiology, P365
[9]  
MANNING J, 1993, ANN EMERG MED, V21, P1058
[10]   RELATION BETWEEN POWER SPECTRUM TIME COURSE DURING VENTRICULAR-FIBRILLATION AND ELECTROMECHANICAL DISSOCIATION - EFFECTS OF CORONARY PERFUSION AND NIFEDIPINE [J].
MARTIN, G ;
COSIN, J ;
SUCH, M ;
HERNANDEZ, A ;
LLAMAS, P .
EUROPEAN HEART JOURNAL, 1986, 7 (07) :560-569