A high stability light emitting diode system for monitoring lead glass electromagnetic calorimeters

被引:21
作者
Autiero, D
BaldoCeolin, M
Bobisut, F
Cardini, A
Cattaneo, P
Cavasinni, V
Conta, C
DelPrete, T
DeSanto, A
Ferrari, R
Flaminio, V
Fraternali, M
Gibin, D
Gninenko, SN
Grabit, R
Guglielmi, A
Iacopini, E
Kovzelev, AV
LaRotonda, L
Lanza, A
Laveder, M
Martelli, F
Mezzetto, M
Pastore, F
Pennacchio, E
Polesello, G
Renzoni, G
Ricci, C
Roda, C
Sconza, A
Stefanini, G
ValdataNappi, M
Veltri, M
Visentin, L
Volkov, SA
机构
[1] UNIV PISA,DIPARTIMENTO FIS,PISA,ITALY
[2] IST NAZL FIS NUCL,PISA,ITALY
[3] UNIV PADUA,DIPARTIMENTO FIS,PADUA,ITALY
[4] IST NAZL FIS NUCL,PADUA,ITALY
[5] UNIV PAVIA,DIPARTIMENTO FIS NUCL & TEOR,I-27100 PAVIA,ITALY
[6] IST NAZL FIS NUCL,PAVIA,ITALY
[7] RUSSIAN ACAD SCI,INST NUCL RES,MOSCOW,RUSSIA
[8] CERN,CH-1211 GENEVA,SWITZERLAND
[9] UNIV FLORENCE,DIPARTIMENTO FIS,I-50144 FLORENCE,ITALY
[10] IST NAZL FIS NUCL,FLORENCE,ITALY
[11] UNIV CALABRIA,DIPARTIMENTO FIS,I-87036 COSENZA,ITALY
[12] IST NAZL FIS NUCL,GRP COLLEGATO COSENZA,COSENZA,ITALY
[13] UNIV URBINO,DIPARTIMENTO FIS,FLORENCE,ITALY
关键词
D O I
10.1016/0168-9002(95)01444-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have designed, built and tested a high stability system based on blue light emitting diodes (LED) and current pulse generators fur calibration and monitoring of lead-glass calorimeters. This apparatus is presently being used for the electromagnetic calorimeter of the WA96 (NOMAD) experiment at CERN. The system was developed to minimize the sensitivity to temperature variations, different loadings, and ageing effects. Tests performed both in the laboratory and in the experiment showed that the response of the lead-glass calorimeter modules to LED light pulses could be kept within the precision of +/-1% for periods of several months.
引用
收藏
页码:556 / 561
页数:6
相关论文
共 9 条
[1]   STUDY OF THE ENERGY CALIBRATION OF A HIGH-RESOLUTION ELECTROMAGNETIC CALORIMETER [J].
BAKKEN, JA ;
BARONE, L ;
BLAISING, JJ ;
BOEHRINGER, T ;
BORGIA, B ;
BOUTIGNY, D ;
BURQ, JP ;
CHEMARIN, M ;
CLARE, R ;
COIGNET, G ;
DENES, P ;
DENOTARISTEFANI, F ;
DIEMOZ, M ;
DIONISI, C ;
ELMAMOUNI, H ;
EXTERMANN, P ;
FALCIANO, S ;
FERRONI, F ;
GRATTA, G ;
ILLE, B ;
KAARET, P ;
KARYOTAKIS, Y ;
KLOK, P ;
LEBRUN, P ;
LECOQ, P ;
LI, PJ ;
LONGO, E ;
LUCKEY, D ;
LUMINARI, L ;
MAIRE, M ;
MARTIN, JP ;
MICKE, M ;
MICKE, U ;
MORAND, G ;
MORGANTI, S ;
OSSMANN, J ;
PIROUE, PA ;
RONDININI, C ;
RUCKSTUHL, W ;
SAUVAGE, G ;
SCHAAD, TP ;
SCHMITZ, D ;
SCHNEEGANS, M ;
STICKLAND, DP ;
SUMNER, RL ;
TAYLOR, C ;
VALENTE, E ;
VIVARGENT, M ;
VUILLEUMIER, L ;
WALK, W .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 280 (01) :25-35
[2]   THE E760 LEAD-GLASS CENTRAL CALORIMETER - DESIGN AND INITIAL TEST-RESULTS [J].
BARTOSZEK, L ;
BHARADWAJ, V ;
CHURCH, MD ;
HAHN, AA ;
PEOPLES, J ;
PORDES, SH ;
RAPIDIS, PA ;
WERKEMA, SJ ;
AGAHI, D ;
BROEMMELSIEK, DR ;
FAST, JE ;
GEE, M ;
GOLLWITZER, KE ;
MANDELKERN, MA ;
MARQUES, JL ;
SCHULTZ, J ;
WEBER, MF ;
GINSBURG, CM ;
MASUZAWA, M ;
RAY, RE ;
ROSEN, JL ;
TROKENHEIM, S ;
ZHAO, JL ;
ARMSTRONG, TA ;
HUFFORD, GE ;
LEWIS, RA ;
MAJEWSKA, AM ;
REID, JD ;
SMITH, GA ;
HASAN, MA ;
BIINO, C ;
PALESTINI, S .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 301 (01) :47-60
[3]   LEAD-GLASS CHERENKOV DETECTOR FOR ELECTRONS AND PHOTONS [J].
BEALE, JS ;
BUSSER, FW ;
CAMILLERI, L ;
DILELLA, L ;
GLADDING, G ;
PLACCI, A ;
POPE, BG ;
SMITH, AM ;
SMITH, B ;
YOH, JK ;
ZAVATTINI, E ;
BLUMENFELD, BJ ;
LEDERMAN, LM ;
COOL, RL ;
LITT, L ;
SEGLER, SL .
NUCLEAR INSTRUMENTS & METHODS, 1974, 117 (02) :501-508
[4]   THE CLEO-II DETECTOR [J].
KUBOTA, Y ;
NELSON, JK ;
PERTICONE, D ;
POLING, R ;
SCHRENK, S ;
ALAM, MS ;
BIAN, ZH ;
CHEN, D ;
KIM, IJ ;
LI, WC ;
LOU, XC ;
NEMATI, B ;
SUN, CR ;
WANG, PN ;
ZOELLER, MM ;
CRAWFORD, G ;
FULTON, R ;
GAN, KK ;
JENSEN, T ;
KAGAN, H ;
KASS, R ;
MALCHOW, R ;
MORROW, F ;
SUNG, MK ;
WHITMORE, J ;
WILSON, P ;
BUTLER, F ;
FU, X ;
KALBFLEISCH, G ;
LAMBRECHT, M ;
SKUBIC, P ;
SNOW, J ;
WANG, PL ;
BORTOLETTO, D ;
BROWN, DN ;
CHEN, WY ;
DOMINICK, J ;
MCILWAIN, RL ;
MILLER, DH ;
MODESITT, M ;
SHIBATA, EI ;
SCHAFFNER, SF ;
SHIPSEY, IPJ ;
YAO, WM ;
BATTLE, M ;
KROHA, H ;
SPARKS, K ;
THORNDIKE, EH ;
WANG, CH ;
STROYNOWSKI, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 320 (1-2) :66-113
[5]   THE EHS LEAD-GLASS CALORIMETERS AND THEIR LASER BASED MONITORING-SYSTEM [J].
POWELL, B ;
HELLER, R ;
IBOLD, N ;
SCHUBERT, KR ;
STIEWE, J ;
VYSOCANSKY, M ;
MAZZUCATO, M ;
ROSSI, P ;
VENTURA, L ;
ZUMERLE, G ;
BORATAV, M ;
DUBOC, J ;
PASSENEAU, J ;
TOUBOUL, MC ;
BAGNAIA, P ;
DIONISI, C ;
ZANELLO, D ;
ZANELLO, L ;
BUJANOV, VM ;
FISJAK, YV ;
KHOLODENKO, AG ;
KISTENEV, EP ;
POLJAKOV, BF ;
CASTELLI, E ;
CHECCHIA, P ;
TRONCON, C .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 198 (2-3) :217-231
[6]  
POWELL B, 1991, NUCL INSTRUM METH A, V305, P275
[7]   PERFORMANCE OF THE VENUS LEAD-GLASS CALORIMETER AT TRISTAN [J].
SUMIYOSHI, T ;
HAYASHI, K ;
OGAWA, K ;
TAKASAKI, F ;
HABA, J ;
KAMITANI, T ;
KANEMATSU, N ;
OSABE, H ;
SUGIMOTO, S ;
YAMASHIT, T ;
SAKANO, M ;
YOSHIDA, H ;
SHINO, K .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 271 (03) :432-441
[8]  
UNPUB NUCL INSTR MET
[9]  
1994, EXPT CERN 1994