Modelling of the coolant flow with heat flow controlled temperature sources in thermal networks

被引:20
作者
Jokinen, T [1 ]
Saari, J [1 ]
机构
[1] Helsinki Univ Technol, Lab Electromech, FIN-02015 Hut, Finland
来源
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS | 1997年 / 144卷 / 05期
关键词
thermal network; electric machine; coolant flow modelling;
D O I
10.1049/ip-epa:19971384
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper deals with modelling a coolant flow in thermal networks. It is shown that the coolant flow can be modelled by heat now controlled temperature sources, Normal circuit analysis programmes can be used to solve this kind of network. The model has been applied to a high-speed induction motor and to a standard induction motor. The test results are compared with the computed temperature values.