Magnetic resonance diagnosis of the anterior labrum and capsule - Effect of field strength on efficacy

被引:19
作者
Allmann, KH
Walter, O
Laubenberger, J
Uhl, M
Buitrago-Tellez, CH
Biebow, N
Langer, M
机构
[1] Freiburg Univ Hosp, Dept Diagnost Radiol, Freiburg, Germany
[2] Freiburg Univ Hosp, Dept Orthoped Surg, Freiburg, Germany
关键词
magnetic resonance imaging; shoulder joint; joint instability; field dependence independence;
D O I
10.1097/00004424-199807000-00007
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
RATIONALE AND OBJECTIVES. The authors compare the performance of high-field and low-held magnetic resonance (MR) systems in the evaluation of shoulder instability, 35 patients were examined at field strengths of 1.0 T and of 0.2 T, METHODS. Surface coils were used in both systems. Because arthroscopy was used as gold standard, a preselected patient-population was obtained for the study. RESULTS. The sensitivity/specificity/accuracy of MR images acquired at 1.0 T for labrum pathology were 91%/67%/91% and 70%/80%/71% for the capsular complex. Compared with the above, the sensitivity/specificity/accuracy for 0.2 T MR images revealed 91%/67%/91% for the labrum pathology and 63%/80%/66% for the capsular complex respectively. In the evaluation of capsular lesions a comparison between the 0.2 T MR system and the 1.0 T system indicated a higher sensitivity and accuracy for the high-field images, Concerning labral lesions, the sensitivity and accuracy of the 0.2 T MR imager and the 1.0 T imager were comparable. CONCLUSIONS. Given differences in imaging protocols, imaging at 0.2 T does not adversely affect the assessment of shoulder instability when compared with imaging at 1.0 T, These preliminary results warrant more extensive clinical comparison of results obtained at different magnetic field strengths.
引用
收藏
页码:415 / 420
页数:6
相关论文
共 21 条
[1]
MR DIAGNOSIS OF INTERNAL DERANGEMENTS OF THE KNEE - EFFECT OF FIELD-STRENGTH ON EFFICACY [J].
BARNETT, MJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (01) :115-118
[2]
GLENOID LABRAL TEARS - PROSPECTIVE EVALUATION WITH MR-IMAGING, MR ARTHROGRAPHY, AND CT ARTHROGRAPHY [J].
CHANDNANI, VP ;
YEAGER, TD ;
DEBERARDINO, T ;
CHRISTENSEN, K ;
GAGLIARDI, JA ;
HEITZ, DR ;
BAIRD, DE ;
HANSEN, MF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (06) :1229-1235
[3]
EFFECT OF ARM ROTATION ON MR IMAGING OF THE ROTATOR CUFF [J].
DAVIS, SJ ;
TERESI, LM ;
BRADLEY, WG ;
RESSLER, JA ;
ETO, RT .
RADIOLOGY, 1991, 181 (01) :265-268
[4]
ACCURACY OF DIAGNOSES FROM MAGNETIC-RESONANCE-IMAGING OF THE KNEE - A MULTICENTER ANALYSIS OF 1014 PATIENTS [J].
FISCHER, SP ;
FOX, JM ;
DELPIZZO, W ;
FRIEDMAN, MJ ;
SNYDER, SJ ;
FERKEL, RD .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (01) :2-10
[5]
HOLT RG, 1990, SKELETAL RADIOL, V19, P5
[6]
MRI VERSUS CT-ARTHROGRAPHY IN THE EVALUATION OF GLENOHUMERAL INSTABILITIES [J].
KREITNER, KF ;
RUNKEL, M ;
GREBE, P ;
JUST, M ;
SCHWEDEN, F ;
OBERBILLIG, C ;
SCHWICKERT, H ;
KIRSCHNER, P ;
SCHILD, HH .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 157 (01) :37-42
[7]
TEARS OF THE GLENOID LABRUM - MR IMAGING OF 88 ARTHROSCOPICALLY CONFIRMED CASES [J].
LEGAN, JM ;
BURKHARD, TK ;
GOFF, WB ;
BALSARA, ZN ;
MARTINEZ, AJ ;
BURKS, DD ;
KALLMAN, DA ;
OBRIEN, TJ ;
LAPOINT, JM .
RADIOLOGY, 1991, 179 (01) :241-246
[8]
THE NORMAL SHOULDER - COMMON VARIATIONS THAT SIMULATE PATHOLOGICAL CONDITIONS AT MR IMAGING [J].
LIOU, JTS ;
WILSON, AJ ;
TOTTY, WG ;
BROWN, JJ .
RADIOLOGY, 1993, 186 (02) :435-441
[9]
RECURRENT ANTERIOR DISLOCATION OF SHOULDER .2. A COMPARATIVE STUDY [J].
MCLAUGHL.HL ;
MACLELLA.DI .
JOURNAL OF TRAUMA, 1967, 7 (02) :191-&
[10]
CT ARTHROGRAPHY OF THE SHOULDER - VARIATIONS OF THE GLENOID LABRUM [J].
MCNIESH, LM ;
CALLAGHAN, JJ .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (05) :963-966