Impact loading in running shoes with cushioning column systems

被引:30
作者
Aguinaldo, A
Mahar, A
机构
[1] Childrens Hosp, Ctr Human Performance, San Diego, CA 92123 USA
[2] Childrens Hosp, Orthoped Biomech Res Ctr, San Diego, CA 92123 USA
关键词
impact force; loading rate; impact attenuation; spring-loaded shoes; rearfoot cushioning technology;
D O I
10.1123/jab.19.4.353
中图分类号
R318 [生物医学工程];
学科分类号
0831 [生物医学工程];
摘要
This study evaluated the effects of running shoes-with two types of cushioning column systems-on impact force patterns during running. Kinematic and ground reaction force data were collected from 10 normal participants wearing shoes with the following cushions: 4-column multicellular urethane elastomer (Shoe 1), 4-column thermoplastic polyester elastomer (Shoe 2), and 1-unit EVA foam (Shoe 3). Participants exhibited significantly lower impact force (p = .02) and loading rate (p = .005) with Shoe 2 (1.84 +/- 0.24 BW; 45.6 +/- 11.6 BW/s) compared to Shoe 1 (1.94 +/- 0.18 BW; 57.9 +/- 12.1 BW/s). Both cushioning column shoes showed impact force characteristics similar to those of a top-model running shoe (Shoe 3), and improved cushioning performance over shoes previously tested in similar conditions. Alterations in impact force patterns induced by lower limb alignment and running speed were negligible since participants did not differ in ankle position, knee position, or speed during all shod running trials. Ankle plantarflexion, however, was higher for barefoot running, indicating an apparent midfoot strike. Mechanical testing of each shoe during physiologic, cyclic loading demonstrated that Shoe 3 had the greatest stiffness, followed by Shoe 2 and Shoe 1. Shoe I was the least stiff of the two shoes with cushioning column systems, yet it displayed a significantly higher impact loading rate during running, possibly due to rearfoot motion alterations induced by the stiffer shoe. This study showed that even in similar shoe types, impact force and loading rate values could vary significantly with midsole cushion constructions. The findings of this study suggest that using these newer running shoes may be effective for runners who want optimal cushioning during running.
引用
收藏
页码:353 / 360
页数:8
相关论文
共 14 条
[1]
3-DIMENSIONAL MEASUREMENT OF REARFOOT MOTION DURING RUNNING [J].
AREBLAD, M ;
NIGG, BM ;
EKSTRAND, J ;
OLSSON, KO ;
EKSTROM, H .
JOURNAL OF BIOMECHANICS, 1990, 23 (09) :933-940
[2]
The role of footwear in minimizing lower limb injury [J].
Barnes, R. A. ;
Smith, P. D. .
JOURNAL OF SPORTS SCIENCES, 1994, 12 (04) :341-353
[3]
GROUND REACTION FORCES IN DISTANCE RUNNING [J].
CAVANAGH, PR ;
LAFORTUNE, MA .
JOURNAL OF BIOMECHANICS, 1980, 13 (05) :397-406
[4]
Cavanagh PR., 1980, The running shoe book
[5]
EFFECTS OF SHOE CUSHIONING UPON GROUND REACTION FORCES IN RUNNING [J].
CLARKE, TE ;
FREDERICK, EC ;
COOPER, LB .
INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1983, 4 (04) :247-251
[6]
Biomechanical variables and the perception of cushioning for running in various types of footwear [J].
Hennig, EM ;
Valiant, GA ;
Liu, Q .
JOURNAL OF APPLIED BIOMECHANICS, 1996, 12 (02) :143-150
[7]
USE OF GROUND REACTION FORCE PARAMETERS IN PREDICTING PEAK TIBIAL ACCELERATIONS IN RUNNING [J].
HENNIG, EM ;
MILANI, TL ;
LAFORTUNE, MA .
JOURNAL OF APPLIED BIOMECHANICS, 1993, 9 (04) :306-314
[8]
James S L, 1978, Am J Sports Med, V6, P40, DOI 10.1177/036354657800600202
[9]
Dominant role of interface over knee angle for cushioning impact loading and regulating initial leg stiffness [J].
Lafortune, MA ;
Hennig, EM ;
Lake, MJ .
JOURNAL OF BIOMECHANICS, 1996, 29 (12) :1523-1529
[10]
INFLUENCE OF TRACK COMPLIANCE ON RUNNING [J].
MCMAHON, TA ;
GREENE, PR .
JOURNAL OF BIOMECHANICS, 1979, 12 (12) :893-904