Transesophageal echocardiography in fetal sheep - A monitoring tool for open and fetoscopic cardiac procedures

被引:17
作者
Kohl, T
Stelnicki, EJ
VanderWall, KJ
Szabo, Z
Ko, E
Bruch, SW
Harrison, MR
Silverman, NH
Hanley, FL
Chou, TM
机构
来源
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES | 1996年 / 10卷 / 08期
关键词
fetal transesophageal echocardiography; intravascular ultrasound catheter; fetal cardiac intervention; fetal cardiac surgery; fetoscopy;
D O I
10.1007/s004649900169
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Cardiac procedures in exteriorized fetuses or assisted by fetoscopy require monitoring capabilities not attended by conventional maternal transabdominal echocardiography. Methods: We, therefore, assessed the potential of fetal transesophageal echocardiography (TEE) utilizing an intravascular ultrasound catheter (IVUC) for fetal cardiac monitoring. We inserted a 10-F-10-MHz IVUC into the esophagus in 12 exteriorized fetal sheep and by a fetoscopic approach in 4 fetal sheep. Cardiac events were observed. Heart rate, cardiac rhythm, patency of the foramen ovale and ductus arteriosus, and the width of the branch pulmonary arteries could be assessed in all fetuses. Ventricular contractility could be assessed only in fetuses weighing less than 2.5 kg. Larger fetuses did not allow adequate imaging of the apical portion of the ventricles because of limited tissue penetration of the IVUC, Fetal TEE permitted placing small guide wires in the cardiac atria and left ventricle. Short-lived premature beats following intracardiac manipulations of these wires could be observed by fetal TEE in all cases. Results: At autopsy, no complications from IVUC insertion were observed in the exteriorized fetuses. Fetoscopic placement of the IVUC resulted in minor perioral skin erosion in two nonexteriorized fetuses. Conclusions: In conclusion, fetal TEE can be achieved with minor fetal injury and may provide useful information during open and fetoscopic cardiac procedures. Further improvements in IVUC design will permit the application of this technique to monitor human fetal cardiac procedures.
引用
收藏
页码:820 / 824
页数:5
相关论文
共 13 条
[1]   SURVIVAL AFTER FETAL AORTIC BALLOON VALVOPLASTY [J].
ALLAN, LD ;
MAXWELL, DJ ;
CARMINATI, M ;
TYNAN, MJ .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1995, 5 (02) :90-91
[2]  
CARPENTER R, J AM COLL CARDIOL, V8, P1434
[3]  
CROMBLEHOLME TM, 1994, SEMIN PERINATOL, V18, P385
[4]   TECHNIQUES FOR INUTERO ENDOSCOPIC SURGERY - A NEW APPROACH FOR FETAL INTERVENTION [J].
ESTES, JM ;
SZABO, Z ;
HARRISON, MR .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1992, 6 (05) :215-218
[5]  
Hanley F L, 1994, Adv Card Surg, V5, P47
[6]   FETAL CARDIAC-SURGERY - STEADY PROGRESS IN THE LABORATORY [J].
HANLEY, FL .
ANNALS OF THORACIC SURGERY, 1994, 57 (02) :279-280
[7]  
HARRISON MR, 1993, WESTERN J MED, V159, P341
[8]  
JENNINGS RW, 1993, SURG GYNECOL OBSTET, V176, P59
[9]  
LOPES LM, 1996, IN PRESS FETAL DIAGN
[10]  
MAXWELL D, 1991, BRIT HEART J, V65, P256