Toxicological screening of urine for drugs by liquid chromatography/time-of-flight mass spectrometry with automated target library search based on elemental formulas

被引:69
作者
Gergov, M
Boucher, B
Ojanperä, I
Vuori, E
机构
[1] Univ Helsinki, Dept Forens Med, FIN-00014 Helsinki, Finland
[2] Appl Biosyst, Framingham, MA USA
关键词
D O I
10.1002/rcm.260
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The present study describes a novel approach for utilizing liquid chromatography/time-of-flight mass spectrometry (LC/TOFMS) in qualitative screening analysis. An LC/TOFMS method was developed for screening toxicologically relevant substances in urine samples. After solid phase extraction and LC separation, the method included full spectrum acquisition followed by automatic internal calibration, searching against a target library, and reporting positive identifications. The target library, containing 433 toxicologically relevant substances in the mass range of 105-734 Da, was created simply by entering the elemental formulas of substances into the instrument software for the calculation of their respective monoisotopic masses. In addition to parent drugs, the library contained selected urinary drug metabolites, based on their structures available in the literature. Identification was based on the exact masses of the compounds. The LC/TOFMS method provided 5-10 ppm mass accuracy for a majority of identified compounds in authentic urine samples. Compared with established thin-layer and gas chromatographic methods, the LC/TOFMS method produced similar findings in urine with the additional advantage of metabolite identification without actual reference substances. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:521 / 526
页数:6
相关论文
共 7 条
  • [1] Cody R.B., 1994, P 42 ASMS C MASS SPE
  • [2] Exact mass measurement of product ions for the structural elucidation of drug metabolites with a tandem quadrupole orthogonal-acceleration time-of-flight mass spectrometer
    Hopfgartner, G
    Chernushevich, IV
    Covey, T
    Plomley, JB
    Bonner, R
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1999, 10 (12) : 1305 - 1314
  • [3] Development of multi-ESI-sprayer, multi-atmospheric-pressure-inlet mass spectrometry and its application to accurate mass measurement using time-of-flight mass spectrometry
    Jiang, LF
    Moini, M
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (01) : 20 - 24
  • [4] Marquet P, 1998, P 46 ASMS C MASS SPE
  • [5] Ojanpera I., 1996, PRACTICAL THIN LAYER, P193
  • [6] Rasanen I, 1996, HRC-J HIGH RES CHROM, V19, P313
  • [7] Quantification and rapid metabolite identification in drug discovery using API time-of-flight LC/MS
    Zhang, NY
    Fountain, ST
    Bi, HG
    Rossi, DT
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (04) : 800 - 806