A readout magnet for prepolarized MRI

被引:39
作者
Morgan, P [1 ]
Conolly, S [1 ]
Scott, G [1 ]
Macovski, A [1 ]
机构
[1] STANFORD UNIV,DEPT ELECT ENGN,MAGNET RESONANCE SYST RES LAB,STANFORD,CA 94305
关键词
repolarized MRI; magnet design;
D O I
10.1002/mrm.1910360405
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Conventional MRI systems rely on large magnets to generate a field that is both strong and extremely uniform. This field is usually produced by a heavy permanent magnet or a cryogenically cooled superconductor. An alternative approach, called prepolarized MRI (PMRI), employs two separate fields produced by two different magnets. A strong and inhomogeneous magnetic field is used to polarize the sample. After polarization, a weak magnetic field is used for readout. These fields can be produced by two separate resistive electromagnets that cost significantly less than a single permanent or superconducting magnet. At Stanford, the authors are constructing a PMRI prototype scanner suitable for imaging human extremities roughly 20 cm in diameter. With this system the authors hope to demonstrate comparable image quality to MRI with reduced system cost. The authors' initial work on low-frequency reception indicates that it will be possible to obtain comparable image signal-to-noise ratio to an MRI scanner operating at the same polarizing field strength. To reduce the capital cost of the system, the authors use resistive electromagnets. Here the authors discuss the full development of the readout magnet including important design considerations, shimming, and field plots. These encouraging results are an important step toward evaluating the cost effectiveness of PMRI.
引用
收藏
页码:527 / 536
页数:10
相关论文
共 31 条
[1]  
[Anonymous], P 3 SCI M SOC MAGN R
[2]  
BARAS P, 1995, P SMR 3 ANN M, P692
[3]   A HIGH-TEMPERATURE SUPERCONDUCTING RECEIVER FOR NUCLEAR-MAGNETIC-RESONANCE MICROSCOPY [J].
BLACK, RD ;
EARLY, TA ;
ROEMER, PB ;
MUELLER, OM ;
MOGROCAMPERO, A ;
TURNER, LG ;
JOHNSON, GA .
SCIENCE, 1993, 259 (5096) :793-795
[4]  
CARLSON J, 1992, SPIE, V1651, P22
[5]  
CARLSON J, 1993, P SMRM 12 ANN M, P1364
[6]   STABILITY AND NOISE PERFORMANCE OF CONSTANT TRANSIMPEDANCE AMPLIFIER WITH INDUCTIVE SOURCE [J].
CHANG, ZY ;
SANSEN, WMC .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS, 1989, 36 (02) :264-271
[7]   OVERCOUPLING NMR PROBES TO IMPROVE TRANSIENT-RESPONSE [J].
CHINGAS, GC .
JOURNAL OF MAGNETIC RESONANCE, 1983, 54 (01) :153-157
[8]  
CONOLLY S, 1995, P SMR 3 ANN M, P935
[9]  
DOBSON K, 1985, AAPM SUMMER SCH, P85
[10]   THE INTRINSIC SIGNAL-TO-NOISE RATIO IN NMR IMAGING [J].
EDELSTEIN, WA ;
GLOVER, GH ;
HARDY, CJ ;
REDINGTON, RW .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (04) :604-618