Flow-through spectrophotometric sensor for the determination of saccharin in low-calorie products

被引:17
作者
Capitán-Vallvey, LF [1 ]
Valencia, MC [1 ]
Nicolás, EA [1 ]
机构
[1] Univ Granada, Fac Sci, Dept Analyt Chem, E-18071 Granada, Spain
来源
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT | 2004年 / 21卷 / 01期
关键词
monoparameter sensor; saccharin; flow-through optical sensor; low calorie products; dietary products;
D O I
10.1080/0265203032000158283
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A simple, rapid and inexpensive monoparameter flow-through sensor has been developed for the determination of saccharin in low calorie and dietary products. The method is based on the transient adsorption of the sweetener on Sephadex G-25 solid phase packed to a height of 20 mm in the flow cell. The optimal transient retention of the synthetic sweetener, in terms of sensitivity and sampling frequency, was obtained when pH 2.75 citric acid-sodium citrate buffer 5x10(-3) M was used as a carrier at a flow-rate of 1.5 ml min(-1) . Saccharin was determined measuring its intrinsic absorbance at 217 nm at its residence time. Calibration graphs for peak height and peak area were linear over the range 5.0-200.0 mug ml(-1) , RSD 1.18%, and 1.0-200.0 mug ml(-1) , RSD 0.78%, respectively. Saccharin was determined in several food samples measuring height or area peak, obtaining recoveries ranging between 98-104 and 99-102% for height and area peak, respectively. The procedure was validated for use in the determination of saccharin in low calorie and dietary products giving reproducible and accurate results.
引用
收藏
页码:32 / 41
页数:10
相关论文
共 36 条
[1]   Simultaneous determination of benzoic acid and saccharin in soft drinks by using lanthanide-sensitized luminescence [J].
Aguilar-Caballos, MP ;
Gómez-Hens, A ;
Pérez-Bendito, D .
ANALYST, 1999, 124 (07) :1079-1084
[2]  
AMER MM, 1978, PHARMAZIE, V33, P435
[3]  
[Anonymous], 1988, ANALYST, V113, P1469
[4]  
[Anonymous], 1978, SPECTROCHIM ACTA, VB33, P242
[5]  
Bosque-Sendra JM, 1998, RRD PURE APPL ANALYT, V1, P115
[6]   Simultaneous determination of antioxidants, preservatives and sweeteners permitted as additives in food by mixed micellar electrokinetic chromatography [J].
Boyce, MC .
JOURNAL OF CHROMATOGRAPHY A, 1999, 847 (1-2) :369-375
[7]  
CAPITANVALLVEY LF, 1996, Patent No. 2079308
[8]   Separation and determination of four artificial sweeteners and citric acid by high-performance anion-exchange chromatography [J].
Chen, QC ;
Mou, SF ;
Liu, KN ;
Yang, ZY ;
Ni, ZM .
JOURNAL OF CHROMATOGRAPHY A, 1997, 771 (1-2) :135-143
[9]  
CONACHER HB, 1970, J ASSOC OFF ANA CHEM, V53, P1117
[10]  
CUNNIFF P, 1995, ANAL AOAC INT, P49