Transvenous biventricular defibrillation halves energy requirements in patients

被引:26
作者
Butter, C
Meisel, E
Tebbenjohanns, J
Engelmann, L
Fleck, E
Schubert, B
Hahn, S
Pfeiffer, D
机构
[1] Humboldt Univ, Charite, Dept Internal Med Cardiol, D-13353 Berlin, Germany
[2] German Heart Inst, D-13353 Berlin, Germany
[3] Heart & Circulat Ctr, Dresden, Germany
[4] Hannover Med Sch, D-3000 Hannover, Germany
[5] Univ Hosp, Leipzig, Germany
[6] Guidant Corp, St Paul, MN USA
关键词
defibrillation; patients; veins;
D O I
10.1161/hc4601.099463
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Defibrillation thresholds (DFT) with standard implantable cardioverter-defibrillator leads in the right ventricle (RV) may be determined by weak shock field intensity in the myocardium of the left ventricle (LV). Adding a shocking electrode in a coronary vein on the middle of the LV free wall, thereby establishing biventricular defibrillation, substantially reduced defibrillation requirements in animals. We investigated the feasibility of this approach in 24 patients receiving an implantable cardioverter-defibrillator using a prototype over-the-wire temporary LV defibrillation lead. Methods and Results-The LV lead was inserted through the coronary sinus, using a guide catheter and guidewire, into a posterior or lateral coronary vein whose location was determined by retrograde venography. Paired DFT testing compared a standard system (RV to superior vena cava plus can emulator [SVC+Can], 60% tilt biphasic shock) to a system including the LV lead. The biventricular system was tested with a dual-shock waveform (20% tilt monophasic shock from LV --> SVC+Can, then 60% tilt biphasic shock from RV --> SVC+Can). Twenty patients completed DFT testing. Venography and LV lead insertion time was 46 +/- 40 minutes. The biventricular system reduced mean DFT by 45% (8.9 +/-1.1 J versus 4.9 +/-0.5 J, P <0.001). Twelve patients (60%) had a standard system DFT :S J, and the biventricular system gave a lower DFT in all patients. There were no adverse events related to the use of the LV lead, which was removed after testing. Conclusions-Internal defibrillation using a transvenously inserted LV lead is feasible, produces significantly lower DFTs, and seems safe under the conditions tested. Biventricular defibrillation may be a useful option for reducing DFTs or could be added to an LV pacing lead for heart failure.
引用
收藏
页码:2533 / 2538
页数:6
相关论文
共 23 条
[1]  
Auricchio A, 1999, AM J CARDIOL, V83, p136D
[2]  
BUTTER C, IN PRESS PACING CLIN
[3]  
de Jongh AL, 1999, PACE, V22, P152, DOI 10.1111/j.1540-8159.1999.tb00323.x
[4]   COMBINATION BIPHASIC WAVE-FORM PLUS SEQUENTIAL PULSE DEFIBRILLATION IMPROVES DEFIBRILLATION EFFICACY OF A NONTHORACOTOMY LEAD SYSTEM [J].
EXNER, D ;
YEE, R ;
JONES, DL ;
KLEIN, GJ ;
MEHRA, R .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1994, 23 (02) :317-322
[5]   Comparison of single- and dual-coil active pectoral defibrillation lead systems [J].
Gold, MR ;
Olsovsky, MR ;
Pelini, MA ;
Peters, RW ;
Shorofsky, SR .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (06) :1391-1394
[6]   EFFECTIVE DEFIBRILLATION IN PIGS USING INTERLEAVED AND COMMON PHASE SEQUENTIAL BIPHASIC SHOCKS [J].
GUSE, PA ;
ROLLINS, DL ;
KRASSOWSKA, W ;
WOLF, PD ;
SMITH, WM ;
IDEKER, RE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (08) :1719-1734
[7]  
HAHN S, 1999, PACE PACING CLIN ELE, V22, P775
[8]  
HAHN S, 1999, PACE PACING CLIN ELE, V22, P720
[9]  
Hahn SJ, 1998, CIRCULATION, V98, P788
[10]   THE SUBCUTANEOUS ARRAY - A NEW LEAD ADJUNCT FOR THE TRANSVENOUS ICD TO LOWER DEFIBRILLATION THRESHOLDS [J].
HIGGINS, SL ;
ALEXANDER, DC ;
KUYPERS, CJ ;
BREWSTER, SA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (08) :1540-1548