Performance evaluations of high-frequency inverter-linked DC/DC converter with noncontact pickup coil

被引:7
作者
Okuno, A [1 ]
Gamage, L
Nakaoka, M
机构
[1] Shinko Elect Co Ltd, R&D Lab, Ise 5168550, Japan
[2] Yamaguchi Univ, Grad Sch Sci & Engn, Yamaguchi 7558611, Japan
关键词
high-frequency inverters; noncontact power transmission;
D O I
10.1109/41.915429
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This letter presents performance evaluations of an inductive coupling power transferring system using a current-source high-frequency transformer resonant inverter which is designed for an electric conveyance. The performance is evaluated on the basis of circuit analysis and feasible experiments. This power conversion system can implement an innovative noncontact power transfer from the viewpoints of less maintenance, controllability, safety, and clean performance.
引用
收藏
页码:475 / 477
页数:3
相关论文
共 4 条
[1]   Sliding transformers for linear contactless power delivery [J].
Barnard, JM ;
Ferreira, JA ;
vanWyk, JD .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1997, 44 (06) :774-779
[2]  
EASSER A, 1995, IEEE IND APPL MAG, V1, P4
[3]  
EASSER A, 1991, IEEE T IND APPL, V27, P4
[4]   A contactless electrical energy transmission system [J].
Pedder, DAG ;
Brown, AD ;
Skinner, JA .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1999, 46 (01) :23-30