Worldwide clinical experience with a new dual-chamber implantable cardioverter defibrillator system

被引:55
作者
Schoels, W
Swerdlow, CD
Jung, W
Stein, KM
Seidl, K
Haffajee, CJ
机构
[1] Univ Heidelberg, Dept Cardiol, D-69115 Heidelberg, Germany
[2] Cedars Sinai Med Ctr, Los Angeles, CA 90048 USA
[3] Univ Bonn, Dept Cardiol, D-5300 Bonn, Germany
[4] Cornell Univ, Coll Med, New York, NY USA
[5] Heart Ctr Ludwigshafen, Ludwigshafen, Germany
[6] St Elizabeths Med Ctr, Boston, MA USA
关键词
implantable cardioverter defibrillator; ventricular tachyarrhythmias; atrial fibrillation;
D O I
10.1046/j.1540-8167.2001.00521.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
New Dual-Chamber ICD. Introduction: Management of atrial tachyarrhythmias represents a significant challenge in patients with implantable cardioverter defibrillators (ICDs). Drug therapy of these arrhythmias is limited by moderate efficacy, ventricular proarrhythmia, and drug-device interactions. This study tested the safety and efficacy of a new dual-chamber ICD to detect and treat atrial as well as ventricular tachyarrhythmias, Methods and Results: A dual-chamber ICD (Medtronic 7250 Jewel AF) was implanted in 293 of 303 patients at 49 centers in Europe, Canada, and North America. Specific data were collected at implant and during a mean follow-up period of 7.9 +/- 4.7 months. There were no clinically evident failures to detect and treat ventricular arrhythmias. In patients with at least one of the dual-chamber detection criteria activated, 1,056 of 1,192 episodes of ventricular tachycardia or fibrillation detected were judged to be appropriate (89 % positive predictive accuracy). Therapy efficacy was 100 % in the ventricular fibrillation zone and 98 % in the ventricular tachycardia zone. Positive predictive accuracy for detection of atrial episodes was 95 % (1,052/1,107), For episodes classified as atrial tachycardia by the device, the efficacy of atrial antitachycardia pacing and high-frequency (50-Hz) burst pacing was 55% and 17%, respectively. High-frequency burst pacing terminated 16.8% of episodes classified as atrial fibrillation, and atrial defibrillation had an estimated efficacy of 76 %. The actuarial estimates of 6-month complication-free survival and total survival were 88 % and 94 %, respectively. Conclusion: This novel dual-chamber ICD is capable of safely and effectively discriminating atrial from ventricular tachyarrhythmias and of treating atrial tachyarrhythmias without compromising detection and treatment of ventricular tachyarrhythmias.
引用
收藏
页码:521 / 528
页数:8
相关论文
共 23 条
[21]   Atrioverter:: An implantable device for the treatment of atrial fibrillation [J].
Wellens, HJJ ;
Lau, CP ;
Lüderitz, B ;
Akhtar, M ;
Waldo, AL ;
Camm, AJ ;
Timmermans, C ;
Tse, HF ;
Jung, W ;
Jordaens, L ;
Ayers, G .
CIRCULATION, 1998, 98 (16) :1651-1656
[22]  
Wilkoff BL, 2001, CIRCULATION, V103, P381
[23]  
Wyse DG, 1998, CIRCULATION, V98, P633