Determination of residues of quinolones in pig muscle comparative study of classical and microwave extraction techniques

被引:52
作者
Hermo, MP [1 ]
Barrón, D [1 ]
Barbosa, J [1 ]
机构
[1] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
liquid chromatography; microwave-assisted extraction (MAE); pig muscle and quinolones;
D O I
10.1016/j.aca.2005.02.070
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents the comparison between two analytical methods used for the determination of quinolones in pig muscle. The procedures involve the extraction of the quinolones from the tissues by traditional extraction and using microwave-assisted extraction (MAE), a step for clean-up and preconcentration of the analytes by solid phase extraction and subsequent liquid chromatography separation with UV absorbance detection. MAE has proven to be an alternative to classical extraction to extract quinolones from pig muscle below the maximum residue limit (MRLs) established by European Community, because less interfering substances were observed and cleaner extracts were obtained and in consequence LOD and LOQ determined are slightly lower than those obtained with classical extraction. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:77 / 82
页数:6
相关论文
共 27 条
[1]   ANALYTICAL STRATEGIES FOR THE SCREENING OF VETERINARY DRUGS AND THEIR RESIDUES IN EDIBLE PRODUCTS [J].
AERTS, MML ;
HOGENBOOM, AC ;
BRINKMAN, UAT .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 667 (01) :1-40
[2]  
[Anonymous], 2001, GUID IND BIOAN METH
[3]   Determination of quinolones in chicken tissues by liquid chromatography with ultraviolet absorbance detection [J].
Bailac, S ;
Ballesteros, O ;
Jiménez-Lozano, E ;
Barrón, D ;
Sanz-Nebot, V ;
Navalón, A ;
Vílchez, JL ;
Barbosa, J .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1029 (1-2) :145-151
[4]   PREFERENTIAL SOLVATION IN ACETONITRILE-WATER MIXTURES - RELATIONSHIP BETWEEN SOLVATOCHROMIC PARAMETERS AND STANDARD PH VALUES [J].
BARBOSA, J ;
SANZNEBOT, V .
JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1994, 90 (21) :3287-3292
[5]   ASSIGNMENT OF REFERENCE PH-VALUES TO PRIMARY STANDARD BUFFER SOLUTIONS FOR STANDARDIZATION OF POTENTIOMETRIC SENSORS IN ACETONITRILE-WATER MIXTURES [J].
BARBOSA, J ;
SANZNEBOT, V .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 353 (02) :148-155
[6]   The application of factor analysis to solvatochromic parameters and pHs values for the standardization of potentiometric sensors in mobile phases used in liquid chromatography [J].
Barbosa, J ;
Marqués, I ;
Barrón, D ;
Sanz-Nebot, V .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1999, 18 (08) :543-549
[7]   Recent applications of sample preparation techniques in food analysis [J].
Buldini, PL ;
Ricci, L ;
Sharma, JL .
JOURNAL OF CHROMATOGRAPHY A, 2002, 975 (01) :47-70
[8]   Recent extraction techniques for solid matrices-supercritical fluid extraction, pressurized fluid extraction and microwave-assisted extraction: their potential and pitfalls [J].
Camel, V .
ANALYST, 2001, 126 (07) :1182-1193
[9]   Analysis of fluoroquinolones in biological fluids by high-performance liquid chromatography [J].
Carlucci, G .
JOURNAL OF CHROMATOGRAPHY A, 1998, 812 (1-2) :343-367
[10]  
*COMM EUR COMM, 1990, DIAR OF COM EUR