Radioulnar load-sharing in the forearm - A study in cadavera

被引:103
作者
Markolf, KL
Lamey, D
Yang, S
Meals, R
Hotchkiss, R
机构
[1] Univ Calif Los Angeles, Rehabil Ctr, Dept Orthopaed Surg, Biomech Res Sect, Los Angeles, CA 90095 USA
[2] Lenox Hill Hosp, Dept Orthoped Surg, New York, NY 10021 USA
[3] Hosp Special Surg, New York, NY 10021 USA
关键词
D O I
10.2106/00004623-199806000-00012
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Custom-designed miniature load-cells were inserted into the distal end of the ulna and the proximal end of the radius in ten fresh-frozen forearms from cadavera, The forces transmitted through the bones at these sites were measured under 134 newtons of constant axial load that was applied through the metacarpals as the forearm was rotated from 60 degrees of supination to 60 degrees of pronation, The simultaneous measurements of these forces allowed the calculation of radioulnar load-sharing at the wrist and the elbow as well as the calculation of the amount of force that was transferred from the radius to the ulna through the interosseous membrane. With the elbow in valgus alignment (that is, with contact between the radial head and the capitellum), the main pathway for load transmission through the forearm was direct axial loading of the radius; measurements from both load-cells were unaffected by the angle of elbow flexion, When the forearm was in neutral rotation, the mean force in the distal end of the ulna averaged 2.8 per cent of the load applied to the wrist and the mean force in the proximal end of the ulna averaged 11.8 per cent; this indicated that only a small amount of tension developed in the interosseous membrane. With the elbow in varus alignment (that is, with no contact between the radial head and the capitellum), load was transmitted through the forearm by a transfer of force from the radius to the ulna through the interosseous membrane. When the forearm was in neutral rotation, the force in the distal end of the ulna averaged 7.0 per cent of the load applied to the wrist and the force in the proximal end of the ulna averaged 93.0 per cent; the force through the interosseous membrane decreased with supination of the forearm. Testing with the elbow in valgus alignment and shortening of the distal end of the radius in two-millimeter increments produced corresponding increases in force in the distal end of the ulna and decreases in force in the radial head. The forces through the interosseous membrane remained low after each amount of radial shortening. CLINICAL RELEVANCE: Transfer of load from the wrist, through the radius and the ulna, to the elbow is a complex event that depends on the position of the forearm, anatomy of the wrist, and soft-tissue linkages between the radius and the ulna, Varus-valgus alignment of the elbow influences the basic mechanism of force transmission through the forearm, The interosseous membrane plays a minimum role in load transmission with the elbow in valgus alignment, Dynamic gripping activities that include varus stress to the elbow would be expected to develop force in the interosseous membrane, Radioulnar load-sharing at the wrist and the elbow changed significantly when the distal end of the radius was shortened by as little as two millimeters (p less than or equal to 0.05), With the elbow in valgus alignment, four millimeters of shortening was required to approximately balance the radioulnar loads at the wrist.
引用
收藏
页码:879 / 888
页数:10
相关论文
共 11 条
[1]
THE LOAD ON THE RADIUS AND ULNA IN DIFFERENT POSITIONS OF THE WRIST AND FOREARM - A CADAVER STUDY [J].
AFEKENSTAM, FW ;
PALMER, AK ;
GLISSON, RR .
ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (03) :363-365
[2]
TRANSMISSION OF PRESSURES ACROSS ELBOW JOINT [J].
HALLS, AA ;
TRAVILL, A .
ANATOMICAL RECORD, 1964, 150 (03) :243-&
[3]
AN ANATOMIC AND MECHANICAL STUDY OF THE INTEROSSEOUS MEMBRANE OF THE FOREARM - PATHOMECHANICS OF PROXIMAL MIGRATION OF THE RADIUS [J].
HOTCHKISS, RN ;
AN, KN ;
SOWA, DT ;
BASTA, S ;
WEILAND, AJ .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1989, 14 (02) :256-261
[4]
FORCE TRANSMISSION THROUGH THE RADIAL HEAD [J].
MORREY, BF ;
AN, KN ;
STORMONT, TJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1988, 70A (02) :250-256
[5]
RADIAL SHORTENING FOR KIENBOCKS DISEASE - FACTORS AFFECTING THE OPERATIVE RESULT [J].
NAKAMURA, R ;
IMAEDA, T ;
MIURA, T .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1990, 15B (01) :40-45
[6]
THE TRIANGULAR FIBROCARTILAGE COMPLEX OF THE WRIST - ANATOMY AND FUNCTION [J].
PALMER, AK ;
WERNER, FW .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1981, 6 (02) :153-162
[7]
PALMER AK, 1984, CLIN ORTHOP RELAT R, P26
[8]
THE ROTE OF THE INTEROSSEOUS MEMBRANE AND TRIANGULAR FIBROCARTILAGE COMPLEX IN FOREARM STABILITY [J].
RABINOWITZ, RS ;
LIGHT, TR ;
HAVEY, RM ;
GOURINENI, P ;
PATWARDHAN, AG ;
SARTORI, MJ ;
VRBOS, L .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1994, 19A (03) :385-393
[9]
FOREARM FORCE TRANSMISSION AFTER SURGICAL-TREATMENT OF DISTAL RADIOULNAR JOINT DISORDERS [J].
TRUMBLE, T ;
GLISSON, RR ;
SEABER, AV ;
URBANIAK, JR .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1987, 12A (02) :196-202
[10]
RADIAL SHORTENING FOR KIENBOCK DISEASE [J].
WEISS, APC ;
WEILAND, AJ ;
MOORE, JR ;
WILGIS, EFS .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (03) :384-391